Assessment of RAdiopaque Patient IDentification Stickers (RAPIDS) for patient-scan correlation in a mass casualty incident
- 1 June 2020
- journal article
- research article
- Published by Springer Science and Business Media LLC in Emergency Radiology
- Vol. 27 (3), 293-301
- https://doi.org/10.1007/s10140-020-01761-w
Abstract
Purpose To qualitatively assess the legibility of radiopaque patient identification stickers and their effect on image quality. These stickers are intended for use as a part of a patient registration and identification pack utilized in a mass casualty incident (MCI), to prevent errors in correlating patients with their diagnostic imaging and reports. Methods Four different prototype designs of stickers with radiopaque identification numbers which are legible on radiographs and CT were created. These were affixed to head and thorax phantoms and scanned using standard imaging protocols. Images were reviewed qualitatively for legibility and the presence of image degradation due to the radiopaque sticker materials using Likert scales by four radiologists and four emergency physicians. Results All four prototypes were confidently legible on forehead, shoulder and sternum on CT on topogram and reconstructed images. Sticker positioning over the temple resulted in unreliable legibility on topogram. All prototypes were confidently legible on shoulder and sternum on CT and radiographs. Significant image degradation was reported on radiographs with sticker position over the sternum. The preferred anatomic position was the forehead. Conclusion In a mass casualty incident, radiopaque patient identification stickers affixed to injured patients may help to ensure confidence in the correlation between patients and their imaging. Tested prototypes were found to be easily legible without substantial degradation of image quality. Preferred anatomical position and construction material was established. Consideration should be given to addition of such radiographic identity aides to MCI patient registration packs.Keywords
This publication has 40 references indexed in Scilit:
- Rural hospital mass casualty response to a terrorist shooting spreeBritish Journal of Surgery, 2013
- Understanding and preventing wrong-patient electronic orders: a randomized controlled trialJournal of the American Medical Informatics Association, 2013
- The initial health-system response to the earthquake in Christchurch, New Zealand, in February, 2011The Lancet, 2012
- The Fort Hood MassacreJournal Of Trauma-Injury Infection and Critical Care, 2012
- Data collection in a live mass casualty incident simulationEuropean Journal of Emergency Medicine, 2012
- Increased Situation Awareness in Major Incidents—Radio Frequency Identification (RFID) Technique: A Promising ToolPrehospital and Disaster Medicine, 2012
- Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolationEuropean Radiology, 2011
- Patient Misidentifications Caused by Errors in Standard Bar Code TechnologyClinical Chemistry, 2010
- Performance and consistency of care in admitted trauma patients: our next great opportunity in trauma care?Anz Journal of Surgery, 2009
- Management of Conventional Mass Casualty Incidents: Ten Commandments for Hospital PlanningJournal of Burn Care & Research, 2006