Abstract
To predict and compare the hypotensive efficacy of three minimally-invasive glaucoma surgery (MIGS) implants through a numerical model. Post-implant hypotensive efficacy was evaluated by using a numerical model and a computational fluid dynamics simulation. Three different devices were compared: the XEN 45 stent (tube diameter, 45 μm), the XEN 63 stent (63 μm) and the PreserFlo microshunt (70 μm). The influence of the filtration bleb pressure (Bp) and tube diameter, length, and position within the anterior chamber (AC) on intraocular pressure (IOP) were evaluated. Using baseline IOPs of 25, 30 and 50 mmHg, respectively, the corresponding computed post-implant IOPs for each device were as follows: XEN 45: 17 mmHg (29% decrease), 19 mmHg (45%) and 20 mmHg (59%) respectively; XEN 63: 13 mmHg (48%), 13 mmHg (62%), and 13 mmHg (73%); PreserFlo: 12 mmHg (59%), 13 mmHg (73%) and 13 mmHg (73%). At a baseline IOP of 35 mmHg with an increase in the outflow resistance within the Bp from 5 to 17 mmHg, the hypotensive efficacy for each device was reduced as follows: XEN45: 54% to 37%; XEN 63: 74% to 46%; and PreserFlo: 75% to 47%. The length and the position of the tube in the AC had only a minimal (non-significant) effect on IOP (<0.1 mmHg). This hydrodynamic/numerical model showed that implant diameter and bleb pressure are the two most pertinent determinants of hypotensive efficacy. In distinction, tube length and position in the AC do not significantly influence IOP.Keywords
Funding Information
- Health Research Institute (IdISSC), Madrid, Spain.
- Health Research Institute Puerta De Hierro-Segovia Arana, Madrid, Spain.
This publication has 62 references indexed in Scilit:
- Experimental research on intraocular aqueous flow by PIV methodBioMedical Engineering OnLine, 2013
- Mechanical responsiveness of the endothelial cell of Schlemm's canal: scope, variability and its potential role in controlling aqueous humour outflowJournal of The Royal Society Interface, 2011
- Computational Modeling of Fluid Flow and Intra-Ocular Pressure following Glaucoma SurgeryPLOS ONE, 2010
- Coupling of HRT II and AS-OCT to evaluate corneal endothelial cell loss and in vivo visualization of the Ahmed glaucoma valve implantEye, 2008
- Lens thickness with age and accommodation by optical coherence tomographyOphthalmic and Physiological Optics, 2008
- Numerical Solution of Ocular Fluid Dynamics in a Rabbit Eye: Parametric EffectsAnnals of Biomedical Engineering, 2006
- Changes in aqueous humor dynamics with age and glaucomaProgress in Retinal and Eye Research, 2005
- 2002 Survey of the American Glaucoma SocietyJournal of Glaucoma, 2005
- Ocular Biomechanics and BiotransportAnnual Review of Biomedical Engineering, 2004
- CELL DETACHMENT DURING SINUSOIDAL REPERFUSION AFTER LIVER PRESERVATIONTransplantation, 1997