How does image quality affect radiologists’ perceived ability for image interpretation and lesion detection in digital mammography?
Open Access
- 21 January 2021
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 31 (7), 5335-5343
- https://doi.org/10.1007/s00330-020-07679-8
Abstract
Objectives: To study how radiologists’ perceived ability to interpret digital mammography (DM) images is affected by decreases in image quality. Methods: One view from 45 DM cases (including 30 cancers) was degraded to six levels each of two acquisition-related issues (lower spatial resolution and increased quantum noise) and three post-processing-related issues (lower and higher contrast and increased correlated noise) seen during clinical evaluation of DM systems. The images were shown to fifteen breast screening radiologists from five countries. Aware of lesion location, the radiologists selected the most-degraded mammogram (indexed from 1 (reference) to 7 (most degraded)) they still felt was acceptable for interpretation. The median selected index, per degradation type, was calculated separately for calcification and soft tissue (including normal) cases. Using the two-sided, non-parametric Mann-Whitney test, the median indices for each case and degradation type were compared. Results: Radiologists were not tolerant to increases (medians: 1.5 (calcifications) and 2 (soft tissue)) or decreases (median: 2, for both types) in contrast, but were more tolerant to correlated noise (median: 3, for both types). Increases in quantum noise were tolerated more for calcifications than for soft tissue cases (medians: 3 vs. 4, p = 0.02). Spatial resolution losses were considered less acceptable for calcification detection than for soft tissue cases (medians: 3.5 vs. 5, p = 0.001). Conclusions: Perceived ability of radiologists for image interpretation in DM was affected not only by image acquisition-related issues but also by image post-processing issues, and some of those issues affected calcification cases more than soft tissue cases. Key Points: • Lower spatial resolution and increased quantum noise affected the radiologists’ perceived ability to interpret calcification cases more than soft tissue lesion or normal cases. • Post-acquisition image processing-related effects, not only image acquisition-related effects, also impact the perceived ability of radiologists to interpret images and detect lesions. • In addition to current practices, post-acquisition image processing-related effects need to also be considered during the testing and evaluation of digital mammography systems.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of Direct Digital Mammography, Computed Radiography, and Film-Screen in the French National Breast Cancer Screening ProgramAmerican Journal of Roentgenology, 2014
- Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer studyMedical Physics, 2012
- VIEWDEX: an efficient and easy-to-use software for observer performance studiesRadiation Protection Dosimetry, 2010
- Digital Mammography: Effects of Reduced Radiation Dose on Diagnostic PerformanceRadiology, 2007
- Current challenges of full field digital mammographyRadiation Protection Dosimetry, 2005
- The Effects of Gray Scale Image Processing on Digital Mammography Interpretation Performance1Academic Radiology, 2005
- Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiographyEuropean Radiology, 2003
- Image Quality of Screening MammographyAmerican Journal of Roentgenology, 2002
- Screening MammographyAmerican Journal of Roentgenology, 2002
- Image Processing Algorithms for Digital Mammography: A Pictorial EssayRadioGraphics, 2000