A scintillator-based range telescope for particle therapy
Open Access
- 18 May 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (16), 165001
- https://doi.org/10.1088/1361-6560/ab9415
Abstract
The commissioning and operation of a particle therapy centre requires an extensive set of detectors for measuring various parameters of the treatment beam. Among the key devices are detectors for beam range quality assurance. In this work, a novel range telescope based on plastic scintillator and read out by a large-scale CMOS sensor is presented. The detector is made of a stack of 49 plastic scintillator sheets with a thickness of 2--3~mm and an active area of $100\times100$~mm$^2$, resulting in a total physical stack thickness of 124.2~mm. This compact design avoids optical artefacts that are common in other scintillation detectors. The range of a proton beam is reconstructed using a novel Bragg curve model that incorporates scintillator quenching effects. Measurements to characterise the performance of the detector were carried out at the Heidelberger Ionenstrahl-Therapiezentrum (HIT, Heidelberg, GER) and the Clatterbridge Cancer Centre (CCC, Bebington, UK). The maximum difference between the measured range and the reference range was found to be 0.41~mm at a proton beam range of 310~mm and was dominated by detector alignment uncertainties. With the new detector prototype, the water-equivalent thickness of PMMA degrader blocks has been reconstructed within $\pm0.1$~mm. An evaluation of the radiation hardness proves that the range reconstruction algorithm is robust following the deposition of 6,300~Gy peak dose into the detector. Furthermore, small variations in the beam spot size and transverse beam position are shown to have a negligible effect on the range reconstruction accuracy. The potential for range measurements of ion beams is also investigated.
Keywords
Funding Information
- H2020 Marie Skłodowska-Curie Actions (675265)
This publication has 37 references indexed in Scilit:
- Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beamsPhysics in Medicine & Biology, 2020
- Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital cameraJournal of Applied Clinical Medical Physics, 2017
- A comprehensive and efficient daily quality assurance for PBS proton therapyPhysics in Medicine & Biology, 2017
- Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapyPhysics in Medicine & Biology, 2016
- Recent developments in Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- The FLUKA Code: An Accurate Simulation Tool for Particle TherapyFrontiers in Oncology, 2016
- Evaluation of detectors for acquisition of pristine depth‐dose curves in pencil beam scanningJournal of Applied Clinical Medical Physics, 2015
- Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector systemMedical Physics, 2012
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003