Non-invasive venous waveform analysis (NIVA) for volume assessment in patients undergoing hemodialysis: an observational study
Open Access
- 24 May 2020
- journal article
- research article
- Published by Springer Science and Business Media LLC in BMC Nephrology
- Vol. 21 (1), 1-8
- https://doi.org/10.1186/s12882-020-01845-2
Abstract
Background Accurate assessment of volume status to direct dialysis remains a clinical challenge. Despite current attempts at volume-directed dialysis, inadequate dialysis and intradialytic hypotension (IDH) are common occurrences. Peripheral venous waveform analysis has recently been developed as a method to accurately determine intravascular volume status through algorithmic quantification of changes in the waveform that occur at different volume states. A noninvasive method to capture peripheral venous signals is described (Non-Invasive Venous waveform Analysis, NIVA). The objective of this proof-of-concept study was to characterize changes in NIVA signal with dialysis. We hypothesized that there would be a change in signal after dialysis and that the rate of intradialytic change in signal would be predictive of IDH. Methods Fifty subjects undergoing inpatient hemodialysis were enrolled. A 10-mm piezoelectric sensor was secured to the middle volar aspect of the wrist on the extremity opposite to the access site. Signals were obtained fifteen minutes before, throughout, and up to fifteen minutes after hemodialysis. Waveforms were analyzed after a fast Fourier transformation and identification of the frequencies corresponding to the cardiac rate, with a NIVA value generated based on the weighted powers of these frequencies. Results Adequate quality (signal to noise ratio > 20) signals pre- and post- dialysis were obtained in 38 patients (76%). NIVA values were significantly lower at the end of dialysis compared to pre-dialysis levels (1.203 vs 0.868, p < 0.05, n = 38). Only 16 patients had adequate signals for analysis throughout dialysis, but in this small cohort the rate of change in NIVA value was predictive of IDH with a sensitivity of 80% and specificity of 100%. Conclusions This observational, proof-of-concept study using a NIVA prototype device suggests that NIVA represents a novel and non-invasive technique that with further development and improvements in signal quality may provide static and continuous measures of volume status to assist with volume directed dialysis and prevent intradialytic hypotension.Keywords
Funding Information
- National Science Foundation (1549576)
This publication has 24 references indexed in Scilit:
- Hemodynamic Instability during Dialysis: The Potential Role of Intradialytic ExerciseBioMed Research International, 2018
- Peripheral i.v. analysis (PIVA) of venous waveforms for volume assessment in patients undergoing haemodialysisBritish Journal of Anaesthesia, 2017
- A brief review of intradialytic hypotension with a focus on survivalSeminars in Dialysis, 2017
- One-Dimensional Haemodynamic Modeling and Wave Dynamics in the Entire Adult CirculationAnnals of Biomedical Engineering, 2015
- Intradialytic Hypotension and Vascular Access ThrombosisJournal of the American Society of Nephrology, 2011
- Peripheral venous pressure waveformCurrent Opinion In Anesthesiology, 2009
- K/DOQI Clinical Practice Guidelines for Cardiovascular Disease in Dialysis PatientsAmerican Journal of Kidney Diseases, 2005
- Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patientsKidney International, 2004
- The effect of frequent or occasional dialysis-associated hypotension on survival of patients on maintenance haemodialysisNephrology Dialysis Transplantation, 2003
- Ultrafiltration and Dry Weight—What Are the Cardiovascular Effects?Artificial Organs, 2003