Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
- 1 November 2020
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 140 (11), 1739-1743
- https://doi.org/10.1007/s00402-020-03432-4
Abstract
Aim This study aims to test the accuracy and feasibility of a measurement of femoral torsion of a 3D C-arm system (Linea aspera method) in a cadaver setting. Materials and methods A total of 11 intact femora were used. Schanz screws were inserted in the femoral bone in a parallel manner with the help of a fixed drill sleeve. Femur bones were then fractured in a controlled manner and three different internal and external torsion angles were fixed with the help of a Goniometer. After that, a 3D scan was performed. The 3D data set was analyzed using a radiologic software (Visage 7, Visage Imaging Inc, USA). Measurements were then compared in the two methods with a dependent t test. Results Specific measurements for different angles did not show any differences between those two utilities. Conclusion Intraoperative estimation of femoral antetorsion using a 3D C-Arm system and the Linea aspera method seems to be an accurate and feasible method. Nevertheless, more studies with higher patient numbers, comparison to CT seems to be the next step and can be recommended.Keywords
This publication has 15 references indexed in Scilit:
- Use of Inherent Anteversion of an Intramedullary Nail to Avoid Malrotation in Comminuted Femur Fractures: A Prospective Case– Control StudyJournal of Orthopaedic Trauma, 2018
- Early versus late intramedullary nailing for traumatic femur fracture management: meta-analysisJournal of Orthopaedic Surgery and Research, 2018
- Intraoperative Correction of Femoral Rotational Deformity Using a Conventional Navigation System and a Smartphone: A Novel TechniqueSurgical Innovation, 2017
- Reliable Method for Avoiding Malrotation Deformity After Intramedullary Nailing of Comminuted Femur Fractures: Clinical Validation of a Previously Described TechniqueJournal of Orthopaedic Trauma, 2017
- Significant differences in femoral torsion values depending on the CT measurement techniqueArchives of orthopaedic and trauma surgery, 2016
- Intra-operative assessment of femoral antetorsion using ISO-C 3D: A cadaver studyInjury, 2014
- Current state of computer-assisted trauma surgeryCurrent Reviews in Musculoskeletal Medicine, 2012
- Accuracy of measurement of femoral anteversion in femoral shaft fractures using a computer imaging software: a cadaveric studyArchives of orthopaedic and trauma surgery, 2011
- Computer-aided methods for assessing lower limb deformities in orthopaedic surgery planningComputerized Medical Imaging and Graphics, 2010
- Rotational Malalignment After Intramedullary Nailing of Femoral FracturesJournal of Orthopaedic Trauma, 2004