Inactivation of Escherichia coli K-12 in Liquid Egg White By a Flow-through Pulsed Uv Light Treatment System
- 1 March 2020
- journal article
- research article
- Published by Elsevier in Journal of Food Protection
- Vol. 83 (3), 418-425
- https://doi.org/10.4315/0362-028x.jfp-19-386
Abstract
Unpasteurized liquid egg can be contaminated with pathogenic microorganisms and may cause foodborne outbreaks. Thus, it is essential to decontaminate the liquid egg to ensure food safety. Pulsed UV light is one of the emerging technologies for food decontamination in recent years. This static treatment system has been studied previously in our laboratory. However, continuous processing using a flow-through treatment system needs to be evaluated for potential commercial applications. Therefore, in this study, a flow-through treatment system of pulsed UV light was evaluated and optimized for inactivation of Escherichia coli K12NSR for liquid egg white decontamination. Treatment factors including flow rate (40 to 80 mL/min), number of passes (one to three passes), and distance from the sample to the pulsed UV light strobe (5 to 13 cm) were optimized using response surface methodology. This methodology suggested three passes with 40 mL/min flow rate and a 5-cm distance as the optimum conditions. The model was then validated for the maximum reduction of E. coli K12NSR, which was measured as 1.57 log CFU/mL at the optimal conditions. The energy doses of the pulsed UV light and temperature changes of the liquid egg white during the treatment were measured. Furthermore, several quality parameters were assessed at the optimum treatment conditions to determine the impact of the flow-through pulsed UV processing on the quality of liquid egg white. The results showed significant differences in pH, lipid oxidation, turbidity, and color between control and pulsed UV light–treated samples (P < 0.05). However, there was no significant difference in foaming ability or foam stability between pulsed UV light–treated samples and the control. Overall, this study demonstrated the potential of flow-through pulsed UV light to decontaminate liquid egg white, but further research is needed for optimal enhancement. The flow-through pulsed UV light treatment on liquid egg white was evaluated. The results suggested three passes with 40 mL/min and a 5-cm distance as the optimum conditions. The maximum reduction of E. coli K-12 obtained was 1.57 log CFU/mL. No significant difference was found in foaming ability or foam stability. Significant differences were observed in pH, lipid oxidation, turbidity, and color.Keywords
This publication has 16 references indexed in Scilit:
- How Can the Value and Use of Egg Yolk Be Increased?Journal of Food Science, 2019
- Selection of Surrogate Bacteria for Use in Food Safety Challenge Studies: A ReviewJournal of Food Protection, 2017
- Decontamination of Hard Cheeses by Pulsed UV LightJournal of Food Protection, 2014
- Effect of irradiation on foaming properties of egg white proteinsPoultry Science, 2009
- Effects of pH and temperature on inactivation of Salmonella typhimurium DT104 in liquid whole egg by pulsed electric fieldsInternational Journal of Food Science & Technology, 2009
- Inactivation of Staphylococcus aureus in Milk and Milk Foam by Pulsed UV-Light Treatment and Surface Response ModelingTransactions of the ASABE, 2008
- Inactivation of Staphylococcus aureus in Milk Using Flow‐Through Pulsed UV‐Light Treatment SystemJournal of Food Science, 2007
- Efficacy of electrolyzed oxidizing water for the microbial safety and quality of eggsPoultry Science, 2004
- Combined effect of high hydrostatic pressure treatment and hydrogen peroxide on Salmonella Enteritidis in liquid whole eggZeitschrift für Lebensmittel-Untersuchung und Forschung, 2003
- XIII—The Development of the CIE 1976 (L* a* b*) Uniform Colour Space and Colour‐difference FormulaJournal of the Society of Dyers and Colourists, 1976