Wear of Denture Teeth by Use of Metal Plates. Part 2: Abrasive Wear of Posterior Teeth.

Abstract
An in vitro study was conducted to evaluate the abrasive wear resistance of high-strength denture teeth (HS teeth). Eight types of specimen were used in the experiments; 3 types of HS teeth, 3 types of conventional plastic denture teeth (PL teeth), porcelain teeth and metal teeth. Sliding-induced wear tests were conducted by sliding the samples on a metal plate. The abrasive wear resistance of the samples was evaluated in terms of wear depth, weight loss and SEM observation. Comparison of wear depth showed that abrasive wear resistance of HS teeth was 4.7 times that of PL teeth, 0.7 times that of porcelain teeth and 8.3 times that of metal teeth. In terms of weight loss, the corresponding values were 3.3-fold, 0.2-fold and 11.4-fold, respectively.