Reproducibility of the cortisol response to stimulation with the low dose (1 μg) of ACTH
- 1 August 1999
- journal article
- research article
- Published by Wiley in Clinical Endocrinology
- Vol. 51 (2), 153-158
- https://doi.org/10.1046/j.1365-2265.1999.00773.x
Abstract
Previous studies have shown that the rapid ACTH stimulation test using a low dose of 1 μg is more sensitive than that using 250 μg ACTH for detecting subtle cases of adrenal insufficiency. However, there are controversies for the reproducibility of the 1 μg-test. To evaluate the reproducibility of the 1 μg-test, we assessed both day-to-day and diurnal variations of cortisol responses to 1 μg ACTH injection. In addition, optimum sampling time for the 1 μg-test was also determined. AND DESIGN Eight healthy volunteers and five patients with secondary adrenal insufficiency were recruited. Healthy subjects were given 1 μg ACTH 3 times in the morning (0800 h) and 2 times in the afternoon (1600 h). Patients with adrenal insufficiency had 2-tests in the morning and 2 in the afternoon. Serum cortisol levels were measured every 10 minutes for 1 h after the injection. In healthy subjects, basal and peak serum cortisol levels were significantly higher in the morning (P < 0.05), whereas maximum cortisol increments were higher in the afternoon (P < 0.001). In patients with adrenal insufficiency, basal and peak serum cortisol levels in the morning were not different from corresponding values in the afternoon. Intra-individual coefficient of variation (CV) of peak serum cortisol response to 1 μg ACTH ranged from 3.0 to 16.4% in healthy subjects and 10.0–34.4% in patients. Also, there was a significant correlation between peak morning or afternoon cortisol levels after 1 μg ACTH injection given in different days in both healthy subjects and patients. Twenty-six of the 40 studies in healthy subjects showed peak response at 20 minutes, while nine showed it at 30 minutes Using the data acquired at 20 and 30 minutes, all 40 studies in healthy subjects showed normal results while none of 20 studies in patients was normal. We conclude that the cortisol response to 1 μg ACTH stimulation was reproducible in both healthy subjects and patients with secondary adrenal insufficiency. In order to assess adrenal function more accurately with the 1 μg ACTH stimulation test, serum cortisol should be measured before and 20 and 30 minutes after ACTH injection.Keywords
This publication has 27 references indexed in Scilit:
- Cortisol, Androstenedione (A4), Dehydroepiandrosterone Sulphate (DHEAS) and 17 Hydroxyprogesterone (17OHP) Responses to Low Doses of (1-24)ACTHJournal of Clinical Endocrinology & Metabolism, 1998
- The Low Dose ACTH Test--A Further Word of CautionJournal of Clinical Endocrinology & Metabolism, 1998
- A low dose ACTH test to assess the function of the hypothalamic–pituitary–adrenal axisClinical Endocrinology, 1996
- The potential for serious consequences from misinterpreting normal responses to the rapid adrenocorticotropin testJournal of Clinical Endocrinology & Metabolism, 1996
- Clinical review 62: Laboratory assessment of adrenal insufficiencyJournal of Clinical Endocrinology & Metabolism, 1994
- Urinary free cortisol values in normal children and adolescentsThe Journal of Pediatrics, 1991
- RE‐EVALUATION OF THE CLINICAL VALUE OF THE 30 MIN ACTH TEST IN ASSESSING THE HYPOTHALAMIC‐PITUITARY‐ADRENOCORTICAL FUNCTIONClinical Endocrinology, 1987
- Discordant Cortisol Response to Exogenous ACTH and Insulin-Induced Hypoglycemia in Patients with Pituitary DiseaseNew England Journal of Medicine, 1982
- Value of an ACTH Test in Assessing Hypothalamic-Pituitary-Adrenocortical Function in Glucocorticoid-treated PatientsBMJ, 1973
- Plasma cortisol response to synacthen (beta-1-24 Ciba) at different times of the day in patients with rheumatic diseases.Annals Of The Rheumatic Diseases, 1967