Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery
- 14 July 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (15), 2307-2319
- https://doi.org/10.1088/0031-9155/48/15/305
Abstract
A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct' imaging of the photon source, special software has been developed to analyse grid field measurements. Besides the source-density function, grid field analysis yields the position of the focal spot in the room laser coordinate system of the linear accelerator and the position of the treatment head rotation axis and the inclination angle of the leaf bank. Thus the method can be used for base dosimetry and for quality assurance in radiosurgery using a microMLC.Keywords
This publication has 20 references indexed in Scilit:
- A multiple source model for 6 MV photon beam dose calculations using Monte CarloPhysics in Medicine & Biology, 2001
- Photon beam characterization and modelling for Monte Carlo treatment planningPhysics in Medicine & Biology, 2000
- Application of a video-optical beam imaging system for quality assurance of medical acceleratorsPhysics in Medicine & Biology, 1998
- A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x‐ray beamsMedical Physics, 1997
- Realization and verification of three-dimensional conformal radiotherapy with modulated fieldsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Precision and accuracy of stereotactic convergent beam irradiations from a linear acceleratorInternational Journal of Radiation Oncology*Biology*Physics, 1994
- X‐ray sources of medical linear accelerators: Focal and extra‐focal radiationMedical Physics, 1993
- Decomposition of pencil beam kernels for fast dose calculations in three‐dimensional treatment planningMedical Physics, 1993
- Measurement of the source size of a 6‐ and 18‐MV radiotherapy linacMedical Physics, 1992