Analgesic Effect of Electric Stimulation of Peripheral Nerves with Different Electric Frequencies Using the Formalin Test
- 1 January 2000
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in The American Journal of Chinese Medicine
- Vol. 28 (2), 291-299
- https://doi.org/10.1142/s0192415x00000349
Abstract
Although electroacupuncture (EA) has been widely used to treat pain, the optimal frequency of EA therapy remains unclear. The study sought to determine the effect of different EA frequencies in a Sprague-Dawley (SD) rat model of pain. Electric stimulation (ES) at frequencies of 2 Hz, 15 Hz or 100 Hz was applied to the ipsilateral or contralateral sciatic nerve of the injected hindpaw of SD rats. Formalin (50 μl, 5%) was subcutaneously injected into the plantar surface of the left hindpaw to induce a nociceptive response. Behavior, including licking and biting, was observed to have two distinct periods, an early phase during the first 5 mins and a late phase from 21-35 mins after injection. The total biting or licking count served as an Indicator of nociceptive response. Our results indicate that ES of the ipsilateral sciatic nerve at a frequency of 2 Hz or 15 Hz reduced the nociceptive responses in both the early and the late phases of the formalin test, whereas ES at 2 Hz had greater antinociceptive effect than ES at 15 Hz in the early phase. No similar analgesic effect in the early phase was observed for ES at 100 Hz. Both pretreatment with ES at 2 Hz and naloxone (3 mg/kg, s.c.) produced a greater antinociceptive response in the late phase than when ES at 2 Hz was delivered immediately after formalin administration. In addition, ES of the neck muscle or contralateral sciatic nerve at a frequency of 2 Hz also decreased licking and biting activity in both phases. The results of this study indicate that different analgesic mechanisms are involved in the response to ES at frequencies of 2 Hz, 15 Hz and 100 Hz, and that ES at 2 Hz has a greater analgesic effect on formalin-induced nociceptive response, especially when it is delivered prior to the onset of pain. The analgesic effect of ES may be mediated via a central origin in the supraspinal level. These findings suggest that 2 Hz may be a good frequency selection for clinical EA applications in analgesia, and that pretreatment with EA at 2 Hz may be an effective method to treat post-operative pain.Keywords
This publication has 23 references indexed in Scilit:
- The formalin test: a validation of the weighted-scores method of behavioural pain ratingPain, 1993
- Analgesia induced by electroacupuncture of different frequencies is mediated by different types of opioid receptors: another cross-tolerance studyBehavioural Brain Research, 1992
- The rat paw formalin test: comparison of noxious agentsPain, 1990
- The analgesic effect of peripheral nerve stimulation in various tests of nociception in ratsActa Physiologica Scandinavica, 1988
- Analgesia by low-frequency nerve stimulation mediated by low-threshold afferents in ratsPain, 1988
- Acupuncture has an analgesic effect in rabbitsPain, 1982
- Electroacupuncture analgesia could be mediated by at least two pain-relieving mechanisms; endorphin and non-endorphin systemsLife Sciences, 1979
- The formalin test: A quantitative study of the analgesic effects of morphine, meperidine, and brain stem stimulation in rats and catsPain, 1977
- Naloxone blockade of acupuncture analgesia: Endorphin implicatedLife Sciences, 1976
- Pain Mechanisms: A New TheoryScience, 1965