Abstract
In the present study, the effects of initial collagen fiber orientation on the medium-term (up to 50 × 106 cycles) fatigue response of heart valve soft tissue biomaterials was investigated. Glutaraldehyde treated bovine pericardium (GLBP), preselected for uniform structure and collagen fiber orientation, was used as the representative heart valve biomaterial. Using specialized instrumentation, GLBP specimens were subjected to cyclic tensile loading to maximum stress levels of 500 ± 50 kPa at a frequency of 22 Hz. Two sample groups were examined, one with the preferred collagen fiber direction parallel (PD) and perpendicular (XD) to the direction of applied strain. The primary findings indicated that GLBP fatigue response was highly sensitive to the direction of loading with respect to fiber orientation. Specifically, when loading perpendicular to the preferred collagen fiber orientation, fiber reorientation is the dominant mechanism. In contrast, when loaded parallel to the preferred fiber direction a reduction in both collagen fiber crimp and fiber reorientation occurred. Moreover, alterations in the degree and direction of mechanical anisotropy can be inducted by cyclic loading when specimens are loaded perpendicular to the preferred fiber direction. Fourier Transform Infrared Spectroscopy (FT-IR) results indicate that molecular-level damage to collagen occurs in both groups after only 20 × 106 cycles. Taken as a whole, the results of this study suggest that initial collagen orientation plays a critical role in bioprosthetic heart valve biomaterial fatigue response. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2007Keywords
This publication has 43 references indexed in Scilit:
- Cyclic loading response of bioprosthetic heart valves: effects of fixation stress state on the collagen fiber architectureBiomaterials, 2005
- Treatment of bioprosthetic heart valve tissue with long chain alcohol solution to lower calcification potentialJournal of Biomedical Materials Research Part A, 2004
- Multiaxial Mechanical Behavior of Biological MaterialsAnnual Review of Biomedical Engineering, 2003
- Aluminum Chloride Pretreatment of Elastin Inhibits Elastolysis by Matrix Metalloproteinases and Leads to Inhibition of Elastin-Oriented CalcificationThe American Journal of Pathology, 2001
- Mechanisms of bioprosthetic heart valve failure: Fatigue causes collagen denaturation and glycosaminoglycan lossJournal of Biomedical Materials Research, 1999
- Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stentsJournal of Biomechanics, 1993
- Pericardial heterograft valves: An assessment of leaflet stresses and their implications for heart valve designJournal of Biomedical Engineering, 1987
- Intermolecular Interactions in Collagen Self-Assembly as Revealed by Fourier Transform Infrared SpectroscopyScience, 1983
- An ‘in vitro’ study of mechanical fatigue in glutaraldehyde-treated porcine aortic valve tissueBiomaterials, 1980
- The infrared spectrum and water binding of collagen as a function of relative humidityPeptide Science, 1971