Automated physical activity monitoring: Validation and comparison with physiological and self‐report measures
- 1 May 1993
- journal article
- research article
- Published by Wiley in Psychophysiology
- Vol. 30 (3), 296-305
- https://doi.org/10.1111/j.1469-8986.1993.tb03356.x
Abstract
Physical activity can be assessed via self-report, via physiological measures such as heart rate and oxygen uptake, or via automated monitor. An electronic accelerometer-based physical activity device (Actigraph) has been reported as an improvement over other activity measurement techniques in terms of utility and accuracy. Four studies provide systematic validation and reliability testing for this device and comparisons with other techniques for assessing daily activities. In the first study, the sensitivity of the Actigraph was determined for differentiating physical activities (walking, running, stair climbing, knee bends) versus sedentary activities (reading, typing, playing video games, and performing a mental arithmetic task). Fifteen healthy adults wore the Actigraph on their wrist during activities; oxygen uptake and heart rate were simultaneously recorded. Results revealed that the Actigraph significantly differentiated between the physical activities (p < .0001) and the sedentary activities (p < .0001). Actigraph counts also correlated significantly with oxygen uptake (r = .73) and heart rate (r = .71) during physical activities (r = .46) and sedentary activities (r = .35), respectively. Test-retest reliability was very high for 12 activities (r = .98). The high level of activity differentiation and strong relationship to oxygen uptake and heart rate suggest the usefulness of this device for behavioral and biomedical studies. However, these studies also indicate that the wrist may not always be the most adequate placement for indexing rate and intensity of daily activities and that further studies are needed to determine the optimal site of monitor attachment. Advantages and disadvantages of self-report, physiological, and automated measures of activity are discussed.Keywords
This publication has 19 references indexed in Scilit:
- Behavioral Triggers of Silent and Symptomatic Myocardial IschemiaJournal of Cardiovascular Electrophysiology, 1991
- Development of a diary for use with ambulatory monitoring of mood, activities, and physiological functionJournal of Psychopathology and Behavioral Assessment, 1990
- Circadian rhythms of activity in healthy young and elderly humansNeurobiology of Aging, 1989
- A prospective study of the reliability and convergent validity of three physical activity measures in a field research trialJournal of Clinical Epidemiology, 1989
- Observations on the design and specification of a wrist-worn human activity monitoring systemBehavior Research Methods, Instruments & Computers, 1985
- The Assessment of Physical Activity in Older Women: Analysis of the Interrelationship and Reliability of Activity Monitoring, Activity Surveys, and Caloric IntakeJournal of Gerontology, 1983
- A new system for long-term recording and processing of heart rate and physical activity in outpatientsComputers and Biomedical Research, 1982
- A human calorimeter for the direct and indirect measurement of 24 h energy expenditureBritish Journal of Nutrition, 1978
- The regulation of body-weight in manProceedings Of The Nutrition Society, 1971