Continuous Speech Recognition in MR Imaging Reporting

Abstract
OBJECTIVE. Our objective was to describe our experience with a commercially available continuous speech recognition system, highlighting the advantages, disadvantages, and costs compared with those of conventional transcription for MR imaging reports.MATERIALS AND METHODS. Data from 5072 reports generated in our MR imaging section during a 9-month period after the implementation of a commercial continuous speech recognition system were compared with 4552 reports produced during the same period 1 year earlier. Information pertaining to the use of continuous speech recognition, report turnaround time, word recognition rate, report appearance, and equipment costs was collected.RESULTS. After its system installation, continuous speech recognition was used to dictate 81.8% of all reports. The mean report turnaround time decreased from 87.8 to 43.6 hr, and report availability at 24 hr increased from 10.5% to 62.5%. The system was found to have an average word recognition accuracy of 92.7% for spontaneous dictat...

This publication has 12 references indexed in Scilit: