Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda
Open Access
- 28 December 2010
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 5 (12), e15206
- https://doi.org/10.1371/journal.pone.0015206
Abstract
Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primostar™ iLED, Lumin™ and AFTER®) for fluorescent detection of Mycobacterium tuberculosis with ZN microscopy on slides prepared from sputum of TB suspects. Examination time for LED-based fluorescent microscopy (LED FM) and ZN slides was also compared, and a qualitative user appraisal of the LED FM systems was carried out. LED FM was between 5.6 and 9.4% more sensitive than ZN microscopy, although the difference was not statistically significant. There was no significant difference in the sensitivity or specificity of the three LED FM systems, although the specificity of Fraen AFTER was somewhat lower than the other LED FM methods. Examination time for LED FM was 2 and 4 times less than for ZN microscopy. LED FM was highly acceptable to Ugandan technologists, although differences in operational performance of the three systems were reported. LED FM compares favourably with ZN microscopy, with equivalent specificity and a modest increase in sensitivity. Screening of slides was substantially quicker using LED FM than ZN, and LED FM was rated highly by laboratory technologists. Available commercial systems have different operational characteristics which should be considered prior to programmatic implementation.Keywords
This publication has 10 references indexed in Scilit:
- Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence MicroscopePLOS ONE, 2010
- Comparison of two LED fluorescence microscopy build-on modules for acid-fast smear microscopy.2010
- Mobile Phone Based Clinical Microscopy for Global Health ApplicationsPLOS ONE, 2009
- Light-emitting diode technologies for TB diagnosis: what is on the market?Expert Review of Medical Devices, 2009
- Performance and acceptability of the FluoLED Easy module for tuberculosis fluorescence microscopy.2008
- Use of Light‐Emitting Diode Fluorescence Microscopy to Detect Acid‐Fast Bacilli in SputumClinical Infectious Diseases, 2008
- Investing time in microscopy: an opportunity to optimise smear-based case detection of tuberculosis.2007
- Light emitting diodes for auramine O fluorescence microscopic screening of Mycobacterium tuberculosis.2006
- Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic reviewThe Lancet Infectious Diseases, 2006
- EXAMINATION FOR TUBERCLE BACILLI BY FLUORESCENCE MICROSCOPY1966