Three-dimensional laparoscopy

Abstract
Background: This study was designed to compare conventional laparoscopy with three-dimensional (3-D) laparoscopy. Method: Thirty candidates, 20 inexperienced and 10 experienced in operative laparoscopy, executed standardized exercises on a pelvitrainer. The candidates were randomized to two groups. Group A executed the exercises first with the conventional and then with the three-dimensional system. Group B accomplished the exercises in the reverse sequence. At the end of the exercises, the candidates answered specific questions about the two systems. Results: A total of 21 h 6 min 6 sec of laparoscopic exercises were analyzed—10 h 8 min 1 sec with the conventional and 10 h 58 min 5 sec with the three-dimensional system (p= 0.38). Group A required 12 h 26 min 56 sec to perform all the exercises. There was no statistically significant difference from group B, where the candidates needed 8 h 39 min 10 sec (p= 0.14). Neither were there any differences in the number of failed attempts between the two groups. There were also no statistical difference when the results obtained from the candidates without experience in laparoscopy and the participants experienced in operative laparoscopy were analyzed separately. Both the inexperienced and the experienced candidates became tired earlier, had more headaches, and needed extra time to adapt to the 3-D system. Conclusion: When analyzed in a standardized fashion, 3-D laparoscopy does not have any significant advantages over conventional laparoscopy.