Abstract
Chemically modified pericardium is commonly used in the fabrication of bioprosthetic heart valves. This material exhibits non-linear elastic behaviour and, as for most other biological soft tissues, it is orthotropic in its extensibility. The influence of the natural orthotropy of pericardium on the mechanical behaviour of pericardial heart valves during the whole cardiac cycle has been studied, using the finite element method. A model of the leaflet of a bicuspid valve has been created, defining the material of the tissue as orthotropic non-linear elastic. Two preferential orthogonal orientations of the tissue have been analysed (axial and circumferential). The results show that even a small amount of orthotropy (an orthotropy index of 1.5 has been used) can significantly affect the mechanical behaviour of the valve, and that an appropriate orientation of the fibres can contribute to optimizing the stress distribution in the leaflets.Keywords
This publication has 14 references indexed in Scilit:
- On the presence of bending stresses in inflated thin-walled structuresProceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 1997
- CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valvesJournal of Biomedical Engineering, 1992
- Calcification and stress distribution in bovine pericardial heart valvesJournal of Biomedical Materials Research, 1992
- Stress/Strain Characteristics of Porcine Mitral Valve Tissue: Parallel Versus Perpendicular Collagen OrientationJournal of Cardiac Surgery, 1992
- Understanding valve/host interactions through explanted valve analysisJournal of Medical Engineering & Technology, 1992
- A three-dimensional analysis of a bioprosthetic heart valveJournal of Biomechanics, 1991
- A preliminary durability study of two types of low-profile pericardial bioprosthetic valves through the use of accelerated fatigue testing and flow characterizationJournal of Biomedical Materials Research, 1989
- The tensile strength of natural and chemically modified bovine pericardiumJournal of Biomedical Materials Research, 1988
- Structure, stress, and tissue repair in aortic valve leafletsCardiovascular Research, 1988
- The standardisation of gauge length: Its influence on the relative extensibility of natural and chemically modified pericardiumJournal of Biomechanics, 1986