Can physiological variables and early warning scoring systems allow early recognition of the deteriorating surgical patient?*
- 1 February 2007
- journal article
- research article
- Published by Ovid Technologies (Wolters Kluwer Health) in Critical Care Medicine
- Vol. 35 (2), 402-409
- https://doi.org/10.1097/01.ccm.0000254826.10520.87
Abstract
Objective: Early warning scoring systems are widely used in clinical practice to allow early recognition of the deteriorating patient, but they lack validation. We aimed to test the ability of physiologic variables, either alone or in existing early scoring systems, to predict major deterioration in a patient’s condition and attempt to derive functions with superior accuracy. Design: A comparative cohort study. Setting: A teaching hospital in Scotland. Patients: Two cohorts of general surgical high-dependency patients. The cohorts are a group of surgical high-dependency care patients who did not require intensive care admission and another group of patients who did require admission. Interventions: None. Measurements and Main Results: Prospective physiologic data on consecutive surgical high-dependency unit patients were collected and compared with physiologic data on patients admitted to the intensive care unit from the same surgical high-dependency units. Data were quality checked and summarized, and discriminant analysis and receiver operator curves were used to discriminate between the groups. There were significant physiologic differences between groups with regard to heart rate (p < .001, area under the receiver operating characteristic curve [AUC] 0.7), respiratory rate (p < .001, AUC 0.71), and oxygen saturation (p < .001, AUC 0.78) across time points. This was not present for systolic blood pressure or temperature. Existing early warning scoring systems had good discriminatory power (AUC 0.83–0.86). We derived discriminant functions, which have a high predictive ability to determine differences between groups (p < .0001, AUC 0.86–0.90). We found that heart rate and respiratory rate could detect differences between groups at 6 and 8 hrs before ICU admission, but oxygen saturation and the discriminant function 2 could detect differences 48 hrs before ICU admission. Conclusions: Some commonly used physiologic variables have reasonable power in determining the difference between patients requiring intensive care unit admission, but others are poor. Existing early warning scores have comparatively good discriminatory power. We have derived functions with excellent predictive power in this derivation cohort.Keywords
This publication has 30 references indexed in Scilit:
- A physiologically‐based early warning score for ward patients: the association between score and outcome*Anaesthesia, 2005
- A comparison of Antecedents to Cardiac Arrests, Deaths and EMergency Intensive care Admissions in Australia and New Zealand, and the United Kingdom—the ACADEMIA studyResuscitation, 2004
- Physiological values and procedures in the 24 h before ICU admission from the wardAnaesthesia, 1999
- Rationing intensive careBMJ, 1995
- Developing strategies to prevent inhospital cardiac arrestCritical Care Medicine, 1994
- Intensive Care Society's APACHE II study in Britain and Ireland--II: Outcome comparisons of intensive care units after adjustment for case mix by the American APACHE II method.BMJ, 1993
- Intensive Care Society's APACHE II study in Britain and Ireland--I: Variations in case mix of adult admissions to general intensive care units and impact on outcome.BMJ, 1993
- Outcomes in intensive care.BMJ, 1993
- Clinical Antecedents to In-Hospital Cardiopulmonary ArrestChest, 1990
- APACHE IICritical Care Medicine, 1985