The series elasticity of heart muscle during hypoxia

Abstract
Using papillary muscle preparations from rat hearts, the compliance of the series elastic element was shown to be decreased during hypoxia. Series elastic compliance was decreased only under conditions resulting also in an alteration of resting length-force relations. It reverted to normal on reoxygenation.