Atmospheric‐pressure laser ionization: a novel ionization method for liquid chromatography/mass spectrometry
Open Access
- 12 January 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (3), 326-336
- https://doi.org/10.1002/rcm.1789
Abstract
We report on the development of a new laser‐ionization (LI) source operating at atmospheric pressure (AP) for liquid chromatography/mass spectrometry (LC/MS) applications. APLI is introduced as a powerful addition to existing AP ionization techniques, in particular atmospheric‐pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI). Replacing the one‐step VUV approach in APPI with step‐wise two‐photon ionization strongly enhances the selectivity of the ionization process. Furthermore, the photon flux during an ionization event is drastically increased over that of APPI, leading to very low detection limits. In addition, the APLI mechanism generally operates primarily directly on the analyte. This allows for very efficient ionization even of non‐polar compounds such as polycyclic aromatic hydrocarbons (PAHs). The APLI source was characterized with a MicroMass Q‐Tof Ultima II analyzer. Both the effluent of an HPLC column containing a number of PAHs (benzo[a]pyrene, fluoranthene, anthracene, fluorene) and samples from direct syringe injection were analyzed with respect to selectivity and sensitivity of the overall system. The liquid phase was vaporized by a conventional APCI inlet (AP probe) with the corona needle removed. Ionization was performed through selective resonance‐enhanced multi‐photon ionization schemes using a high‐repetition‐rate fixed‐frequency excimer laser operating at 248 nm. Detection limits well within the low‐fmol regime are readily obtained for various aromatic hydrocarbons that exhibit long‐lived electronic states at the energy level of the first photon. Only molecular ions are generated at the low laser fluxes employed (∼1 MW/cm2). The design and performance of the laser‐ionization source are presented along with results of the analysis of aromatic hydrocarbons. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
Funding Information
- State of NRW, Germany
This publication has 57 references indexed in Scilit:
- Real-Time, On-Line Characterization of Diesel Generator Air Toxic Emissions by Resonance-Enhanced Multiphoton Ionization Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2004
- Real-Time Monitoring of 4-Vinylguaiacol, Guaiacol, and Phenol during Coffee Roasting by Resonant Laser Ionization Time-of-Flight Mass SpectrometryJournal of Agricultural and Food Chemistry, 2003
- A man-portable, photoionization time-of-flight mass spectrometerField Analytical Chemistry & Technology, 2000
- Scheme for collinear ionization in supersonic jet/multiphoton ionization/time-of-flight mass spectrometryAnalytica Chimica Acta, 2000
- Coordination-Ionspray-MS (CIS-MS), a Universal Detection and Characterization Method for Direct Coupling with Separation TechniquesAngewandte Chemie-International Edition, 1999
- High intensity laser mass spectrometry — a reviewInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Jet-REMPI for the Detection of Trace Gas Compounds in Complex Gas Mixtures, a Tool for Kinetic Research and Incinerator Process ControlCombustion Science and Technology, 1996
- Multiphoton Spectroscopy of Molecular SpeciesAnnual Review of Physical Chemistry, 1994
- Measurement of CO pressures in the ultrahigh vacuum regime using resonance-enhanced multiphoton-ionization time-of-flight mass spectroscopyJournal of Vacuum Science & Technology A, 1993
- Liquid-phase photoionization detector for liquid chromatographyAnalytical Chemistry, 1982