Abstract
In this work, plutonium aerosol generated from a plutonium reprocessing facility is filtered by a six-stage High Efficiency Particulate Air (HEPA) filter system and analyzed in laboratory within a week. Through on-line monitoring of number concentration of particles above 10 nm by a commercial condensation particle counter and off-line monitoring of 239Pu activity concentration by 242Pu isotope dilution Inductively-Coupled Plasma Mass Spectrometry (ICP-MS), it is confirmed that the HEPA filter system works properly during the field operation. Direct determination of plutonium aerosol by two types of ICP-MS, Finnigan ELEMENT ICP-MS and Nu MC-ICP-MS, has been conducted. The results show that the detection limits of ELEMENT and Nu for plutonium concentration are 5.0 × 10−3 Bq/m3 and 5.5 × 10−4 Bq/m3, respectively. Plutonium concentrations in the filtered gas samples are on the order of 2.0 × 10−2 Bq/m3 while the blank value is 5.7 × 10−3 Bq/m3. It's discovered that some plutonium nanoparticles have penetrated the six-stage HEPA filter system. This phenomenon is also observed in the repeated works of last two years. The size of the penetrated plutonium nanoparticles is investigated by ELEMENT in single particle mode. The preliminary results indicate that the penetrated plutonium nanoparticles are smaller than 10 nm and assume the form of 239PuO2.Keywords
This publication has 28 references indexed in Scilit:
- Preliminary study on aerosol particle addition calibration method for on-line quantitative analysis of airborne radioactive particles with ICP-MSInternational Journal of Environmental Analytical Chemistry, 2011
- Comment on: Penetration of Ultrafine Particles and Ion Clusters Through Wire Screens by Ichitsubo et al.Aerosol Science and Technology, 2006
- Filtration Efficiency of Aerosol Particles Below 20 NanometersAerosol Science and Technology, 2005
- Uranium colloid analysis by single particle inductively coupled plasma-mass spectrometryTalanta, 2005
- Thorium colloid analysis by single particle inductively coupled plasma-mass spectrometryTalanta, 2003
- Colloid analysis by single particle inductively coupled plasma-mass spectroscopy: a feasibility studyColloids and Surfaces A: Physicochemical and Engineering Aspects, 2003
- Determination of zinc in individual airborne particles by inductively coupled plasma mass spectrometry with digital signal processingJournal of Analytical Atomic Spectrometry, 2002
- Penetration of Nanometer-Sized Aerosol Particles Through Wire Screen and Laminar Flow TubeAerosol Science and Technology, 1997
- Penetration of Ultrafine Particles and Ion Clusters Through Wire ScreensAerosol Science and Technology, 1996
- Optimization of Operating Conditions in Individual Airborne Particle Analysis by Inductively Coupled Plasma Mass SpectrometryAnalytical Sciences, 1994