Body MR Imaging at 3.0 T: Understanding the Opportunities and Challenges
- 1 September 2007
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 27 (5), 1445-1462
- https://doi.org/10.1148/rg.275065204
Abstract
The development of high-field-strength magnetic resonance (MR) imaging systems has been driven in part by expected improvements in signal-to-noise ratio, contrast-to-noise ratio, spatial-temporal resolution trade-off, and spectral resolution. However, the transition from 1.5- to 3.0-T MR imaging is not straightforward. Compared with body imaging at lower field strength, body imaging at 3.0 T results in altered relaxation times, augmented and new artifacts, changes in chemical shift effects, and a dramatic increase in power deposition, all of which must be accounted for when developing imaging protocols. Inhomogeneities in the static magnetic field and the radiofrequency field at 3.0 T necessitate alterations in the design of coils and other hardware and new approaches to pulse sequence design. Techniques to reduce total body heating are demanded by the physics governing the specific absorption rate. Furthermore, the siting and maintenance of 3.0-T MR imaging systems are complicated by additional safety hazards unique to high-field-strength magnets. These aspects of 3.0-T body imaging represent current challenges and opportunities for radiology practice.Keywords
This publication has 35 references indexed in Scilit:
- Abdominal MRI at 3.0 T: The Basics RevisitedAmerican Journal of Roentgenology, 2006
- Efficient high‐frequency body coil for high‐field MRIMagnetic Resonance in Medicine, 2004
- Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteriesMagnetic Resonance Imaging, 2002
- Dielectric Resonance Phenomena in Ultra High Field MRIJournal of Computer Assisted Tomography, 1999
- A spiral volume coil for improved RF field homogeneity at high static magnetic field strengthMagnetic Resonance in Medicine, 1998
- Dual surface coil with high-B1 homogeneity for deep organ MR imagingMagnetic Resonance Imaging, 1997
- How much contrast is enough? Dependence of enhancement on field strength and MR pulse sequenceEuropean Radiology, 1997
- The NMR phased arrayMagnetic Resonance in Medicine, 1990
- 3-D FLASH Imaging Using a Single Surface Coil and a New Adiabatic Pulse, BIR-4Investigative Radiology, 1990
- Relaxation of solvent protons by paramagnetic ions and its dependence on magnetic field and chemical environment: implications for NMR imagingMagnetic Resonance in Medicine, 1984