Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles
- 1 March 1999
- journal article
- research article
- Published by Springer Science and Business Media LLC in Medical & Biological Engineering & Computing
- Vol. 37 (2), 155-161
- https://doi.org/10.1007/bf02513282
Abstract
Human movement analysis using stereophotogrammetry is based on the reconstruction of the instantaneous laboratory position of selected bony anatomical landmarks (AL). For this purpose, knowledge of an AL's position in relevant bone-embedded frames is required. Because ALs are not points but relatively large and curved areas, their identification by palpation or other means is subject to both intra- and inter-examiner variability. In addition, the local position of ALs, as reconstructed using anad hoc experimental procedure (AL calibration), is affected by photogrammetric errors. The intra- and inter-examiner precision with which local positions of pelvis and lower limb palpable bony ALs can be identified and reconstructed were experimentally assessed. Six examiners and two subjects participated in the study. Intra- and inter-examiner precision (RMS distance from the mean position) resulted in the range 6–21 mm and 13–25 mm, respectively. Propagation of the imprecision of ALs to the orientation of bone-embedded anatomical frames and to hip, knee and ankle joint angles was assessed. Results showed that this imprecision may cause distortion in joint angle against time functions to the extent that information relative to angular movements in the range of 10 degrees or lower may be concealed. Bone geometry parameters estimated using the same data showed that the relevant precision does not allow for reliable bone geometry description. These findings, together with those relative to skin movement artefacts reported elswhere, assist the human movement analyst's consciousness of the possible limitations involved in 3D movement analysis using stereophotogrammetry and call for improvements of the relevant experimental protocols.Keywords
This publication has 24 references indexed in Scilit:
- 3-D attitude representation of human joints: A standardization proposalJournal of Biomechanics, 1994
- Determining the movements of the skeleton using well-configured markersJournal of Biomechanics, 1993
- Precision and accuracy of bone landmarks in characterizing hand and wrist positionJournal of Biomedical Engineering, 1993
- A procedure to validate three-dimensional motion assessment systemsJournal of Biomechanics, 1993
- On the estimation of joint kinematics during gaitJournal of Biomechanics, 1991
- Measurement of lower extremity kinematics during level walkingJournal of Orthopaedic Research, 1990
- A comparison of the accuracy of several hip center location prediction methodsJournal of Biomechanics, 1990
- A three-dimensional musculoskeletal model for gait analysis. Anatomical variability estimatesJournal of Biomechanics, 1989
- A least-squares algorithm for the equiform transformation from spatial marker co-ordinatesJournal of Biomechanics, 1988
- Rigid body motion calculated from spatial co-ordinates of markersJournal of Biomechanics, 1980