Abstract
Pulse wave analysis (PWA) allows cardiac output (CO) measurement after calibration by transpulmonary thermodilution. A PWA system that does not require previous calibration, the FloTrac/Vigileo (FTV), has been recently developed. We compared determinations of CO made with the FTV to simultaneous measurements using transesophageal echocardiography (TEE). Ten ASA I-II patients scheduled for laparoscopic colorectal surgery were studied. A radial 20-gauge cannula was inserted and connected to a hemodynamic monitor and a FTV system for PWA and determination of CO (CO(PWA)). TEE CO (CO(TEE)) was determined as previously described. Measurements were made after intubation, 5 min after establishing the lithotomy position, 5 min after establishing pneumoperitoneum, every 30 min, or each time mean arterial blood pressure decreased below basal values. Statistical analysis was made with the Bland and Altman method. Eighty-eight measurements were compared. The CO(TEE) values ranged from 3.23 to 12 Lt/min (mean 6.21 +/- 1.85). Values for CO(PWA) ranged from 2.9 to 8.5 Lt/min (mean 4.84 +/- 1.14). Bias was 1.17 and limits of agreement -2.02 and 4.37. The percentage error between all CO(TEE) and CO(PWA) measurements was 40% (27%-50%) mean (range). During laparoscopic colon surgery, clinically important differences were observed between CO determinations made with TEE and FTV.Keywords
This publication has 23 references indexed in Scilit:
- Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysisBritish Journal of Anaesthesia, 2007
- Retracted: Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgeryBritish Journal of Anaesthesia, 2007
- A pilot assessment of the FloTracTM cardiac output monitoring systemIntensive Care Medicine, 2006
- Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methodsEuropean Journal of Clinical Pharmacology, 2006
- Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurementsCritical Care, 2006
- Cardiothoracic Anesthesia, Respiration and Airway Cardiac output by PulseCO™ is not interchangeable with thermodilution in patients undergoing OPCABCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patientsBritish Journal of Anaesthesia, 1999
- Pulmonary artery catheterization in anaesthesia and intensive careBritish Journal of Anaesthesia, 1998
- Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped CatheterNew England Journal of Medicine, 1970
- Measurement of cardiac output by thermal dilution in man.Journal of Applied Physiology, 1968