The use of ICP-MS for determination of 129I in environmental samples is complicated by interference from 129Xe+ originating from Xe present as an impurity in Ar plasma gas and by 127IH2 + derived from 127I in samples. Collision cell and reaction cell techniques have been used to reduce such interference. Here, we used ICP-MS with the dynamic reaction cell (DRC) and axial field technology (AFT) to improve 129I determination. The response characteristics of DRC-ICP-MS to test solutions with various 129I and 127I concentrations were investigated after instrument optimization. We eliminated 129Xe+ interference by using O2 as the reaction gas, and we effectively reduced 127IH2 + interference by applying a negative AFT voltage and removing traces of H2 and H2O from the reaction gas. Consequently, the background count ratio (mass 129/mass 127) decreased to the 10−8 level. However, the relationship between the signal at mass 129 and 129I concentration was nonlinear, and we attributed the nonlinearity to sensitivity degradation due to abundant 127I in the matrix. Using a Rh internal standard, we corrected the sensitivity degradation and obtained a linear relationship between mass 129/mass 103 and 129I concentration. The detection limit for 129I in a 1 mg mL−1 127I matrix was 15.2 pg mL−1, which is equivalent to an 129I/127I ratio of 1.5 × 10−8. The developed method was used to determine 129I in soil samples obtained from the land surrounding the nuclear fuel reprocessing plant in Tokai, Japan. The measured 129I/127I ratios (2.6 × 10−8 to 4.7 × 10−7) agreed with the ratios determined by tandetron accelerator mass spectrometry.Keywords
This publication has 27 references indexed in Scilit:
- A review on speciation of iodine-129 in the environmental and biological samplesAnalytica Chimica Acta, 2009
- Analysis of 129I in groundwater samples: Direct and quantitative results below the drinking water standardApplied Geochemistry, 2007
- Chemical Resolution of Pu+ from U+ and Am+ Using a Band-Pass Reaction Cell Inductively Coupled Plasma Mass SpectrometerAnalytical Chemistry, 2004
- Collision and reaction cells in atomic mass spectrometry: development, status, and applicationsThe opinions expressed in the following article are entirely those of the authors and do not necessarily represent the views of the Royal Society of Chemistry, the Editor or the Editorial Board of JAAS.Journal of Analytical Atomic Spectrometry, 2004
- Determination of 129I/127I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cellJournal of Analytical Atomic Spectrometry, 2003
- Improvement of abundance sensitivity in a quadrupole-based ICP-MS instrument with a hexapole collision cellJournal of Analytical Atomic Spectrometry, 2002
- Determination of thorium and uranium isotope ratios in low-concentration geological materials using a fixed multi-collector-ICP-MSJournal of Analytical Atomic Spectrometry, 2001
- Variations inChemical Geology, 1998
- Determination of129I and127I in environmental samples by neutron activation analysis (NAA) and inductively coupled plasma mass spectrometry (ICP-MS)Journal of Radioanalytical and Nuclear Chemistry, 1995
- Iodine-129 and iodine-127 in environmental samples collected from Tokaimura/Ibaraki, JapanScience of The Total Environment, 1986