Performance comparison of capacitor-run induction motors supplied from AC voltage regulator and SPWM AC chopper
- 30 May 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 53 (3), 990-993
- https://doi.org/10.1109/TIE.2006.874256
Abstract
This letter systematically investigates and compares the performance characteristics of a variable-speed capacitor-run induction motor driving a domestic fan load using an ac voltage regulator and a single pulsewidth-modulated (SPWM) ac chopper. This proposal is a significant break from the conventional conclusion since it is shown that the SPWM ac chopper is inferior to the phase angle control scheme for a capacitor-run motor load.Keywords
This publication has 7 references indexed in Scilit:
- An improved energy-saving scheme for capacitor-run induction motorIEEE Transactions on Industrial Electronics, 2001
- A new configuration of single-phase symmetrical PWM AC chopper voltage controllerIEEE Transactions on Industrial Electronics, 1999
- Steady-state modeling, analysis, and performance of transistor-controlled AC power conditioning systemsIEEE Transactions on Power Electronics, 1990
- Microprocessor based harmonic elimination in chopper type AC voltage regulatorsIEEE Transactions on Power Electronics, 1990
- An improved PWM technique for AC choppersIEEE Transactions on Power Electronics, 1989
- Symmetrically Pulse Width Modulated AC ChopperIEEE Transactions on Industrial Electronics and Control Instrumentation, 1977
- The Analysis of Induction Machines Controlled by Series Connected Semiconductor SwitchesIEEE Transactions on Power Apparatus and Systems, 1968