Automated measurement of uptake in cerebellum, liver, and aortic arch in full‐body FDG PET/CT scans
- 14 May 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (6Part1), 3112-3123
- https://doi.org/10.1118/1.4711815
Abstract
Purpose: The purpose of this work was to develop and validate fully automated methods for uptake measurement of cerebellum, liver, and aortic arch in full-body PET/CT scans. Such measurements are of interest in the context of uptake normalization for quantitative assessment of metabolic activity and/or automated image quality control. Methods: Cerebellum, liver, and aortic arch regions were segmented with different automated approaches. Cerebella were segmented in PET volumes by means of a robust active shape model (ASM) based method. For liver segmentation, a largest possible hyperellipsoid was fitted to the liver in PET scans. The aortic arch was first segmented in CTimages of a PET/CT scan by a tubular structure analysis approach, and the segmented result was then mapped to the corresponding PET scan. For each of the segmented structures, the average standardized uptake value (SUV) was calculated. To generate an independent reference standard for method validation, expert image analysts were asked to segment several cross sections of each of the three structures in 134 F-18 fluorodeoxyglucose (FDG) PET/CT scans. For each case, the true average SUV was estimated by utilizing statistical models and served as the independent reference standard. Results: For automated aorta and liver SUV measurements, no statistically significant scale or shift differences were observed between automated results and the independent standard. In the case of the cerebellum, the scale and shift were not significantly different, if measured in the same cross sections that were utilized for generating the reference. In contrast, automated results were scaled 5% lower on average although not shifted, if FDG uptake was calculated from the whole segmented cerebellum volume. The estimated reduction in total SUV measurement error ranged between 54.7% and 99.2%, and the reduction was found to be statistically significant for cerebellum and aortic arch. Conclusions: With the proposed methods, the authors have demonstrated that automated SUV uptake measurements in cerebellum, liver, and aortic arch agree with expert-defined independent standards. The proposed methods were found to be accurate and showed less intra- and interobserver variability, compared to manual analysis. The approach provides an alternative to manual uptake quantification, which is time-consuming. Such an approach will be important for application of quantitative PETimaging to large scale clinical trials.Keywords
Funding Information
- National Institutes of Health (U01CA140206)
- National Cancer Institute (U01CA140206)
- National Institutes of Health (R01EB004640)
- National Institute of Biomedical Imaging and Bioengineering (R01EB004640)
- National Institutes of Health (R01HL111453)
- National Heart, Lung, and Blood Institute (R01HL111453)
This publication has 18 references indexed in Scilit:
- Dual-modality brain PET-CT image segmentation based on adaptive use of functional and anatomical informationComputerized Medical Imaging and Graphics, 2012
- Automated PET-guided liver segmentation from low-contrast CT volumes using probabilistic atlasComputer Methods and Programs in Biomedicine, 2011
- Extracting Curve Skeletons from Gray Value Images for Virtual EndoscopyLecture Notes in Computer Science, 2008
- Comparison of lesion-to-cerebellum uptake ratios and standardized uptake values in the evaluation of lung nodules with 18F-FDG PETNuclear Medicine Communications, 2007
- Flux driven automatic centerline extractionMedical Image Analysis, 2005
- A linear time algorithm for computing exact Euclidean distance transforms of binary images in arbitrary dimensionsIeee Transactions On Pattern Analysis and Machine Intelligence, 2003
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995
- Inference from Iterative Simulation Using Multiple SequencesStatistical Science, 1992
- Surface shape and curvature scalesImage and Vision Computing, 1992
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987