Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics
- 22 December 2008
- journal article
- review article
- Published by Walter de Gruyter GmbH in cclm
- Vol. 47 (2), 143-153
- https://doi.org/10.1515/cclm.2009.045
Abstract
Laboratory diagnostics, a pivotal part of clinical decision making, is no safer than other areas of healthcare, with most errors occurring in the manually intensive preanalytical process. Patient misidentification errors are potentially associated with the worst clinical outcome due to the potential for misdiagnosis and inappropriate therapy. While it is misleadingly assumed that identification errors occur at a low frequency in clinical laboratories, misidentification of general laboratory specimens is around 1% and can produce serious harm to patients, when not promptly detected. This article focuses on this challenging issue, providing an overview on the prevalence and leading causes of identification errors, analyzing the potential adverse consequences, and providing tentative guidelines for detection and prevention based on direct-positive identification, the use of information technology for data entry, automated systems for patient identification and specimen labeling, two or more identifiers during sample collection and delta check technology to identify significant variance of results from historical values. Once misidentification is detected, rejection and recollection is the most suitable approach to manage the specimen. Clin Chem Lab Med 2009;47:143–53.Keywords
This publication has 45 references indexed in Scilit:
- A flexible polymer tube lab-chip integrated with microsensors for smart microcatheterBiomedical Microdevices, 2008
- Computer-Assisted Bar-Coding System Significantly Reduces Clinical Laboratory Specimen Identification Errors in a Pediatric Oncology HospitalThe Journal of Pediatrics, 2008
- The Long Road to Patient SafetyJAMA, 2005
- Impact of Bar Coding Technology and Computerized Physician Order Entry on Reducing Laboratory Specimen Misidentification Errors in the Emergency DepartmentAcademic Emergency Medicine, 2005
- Safe health care: are we up to it?BMJ, 2000
- Interference with an Implantable Defibrillator by an Electronic Antitheft-Surveillance DeviceNew England Journal of Medicine, 1998
- Toward optimal laboratory use. Problems in laboratory testing in primary careJAMA, 1996
- Monitoring transfusionist practices: a strategy for improving transfusion safetyTransfusion, 1994
- Reports of 355 transfusion‐associated deaths: 1976 through 1985Transfusion, 1990
- Continuous Improvement as an Ideal in Health CareNew England Journal of Medicine, 1989