A novel polymer for potential use in a trileaflet heart valve
- 28 April 2006
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 79B (2), 325-334
- https://doi.org/10.1002/jbm.b.30546
Abstract
A novel polyolefin, poly(styrene-b-isobutylene-b-styrene) (Quatromer™), is being proposed as a viable polymer for use in trileaflet heart valves because of its oxidative stability. The current study was designed to assess the polymer's hemocompatibility and mechanical durability. Mechanical characterization included static tensile tests and dynamic tension–tension and bending fatigue tests, where the properties of isotropic and composite (polypropylene (PP) embedded) Quatromer specimens were compared with those of a polyurethane (PUR) approved for cardiovascular applications. It was found that by embedding PP fibers into the Quatromer matrix, the tensile and fatigue properties of the polymer could be improved, making them comparable, if not better than the PUR. The thrombotic potential of Quatromer was compared with the PUR, glutaraldehyde-fixed porcine valve material, and a positive and negative control by measuring platelet deposition with radiolabeled platelets in a parallel plate flow configuration. The porcine valve material was found to have significantly higher platelet deposition under all flow regimes, while no significant difference existed between Quatromer and PUR. In conclusion, Quatromer is shown to have suitable hemocompatibility and mechanical durability for use in polymer trileaflet heart valves, and fiber reinforcement can effectively be used to tailor the mechanical properties. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006Keywords
This publication has 32 references indexed in Scilit:
- Flow‐induced Platelet Activation in a St. Jude Mechanical Heart Valve, a Trileaflet Polymeric Heart Valve, and a St. Jude Tissue ValveArtificial Organs, 2005
- Biodegradation of polyurethane under fatigue loadingJournal of Biomedical Materials Research, 2003
- A nonlinear anisotropic model for porcine aortic heart valvesJournal of Biomechanics, 2001
- Heart valves: which is the best choice?Cardiovascular Surgery, 1999
- In Vitro Function and Durability Assessment of a Novel Polyurethane Heart Valve ProsthesisArtificial Organs, 1996
- Calcification and fatigue failure in a polyurethane heart valveBiomaterials, 1995
- A synthetic three-leaflet valveJournal of Medical Engineering & Technology, 1992
- Composite Technology for Total Hip ArthroplastyPublished by Ovid Technologies (Wolters Kluwer Health) ,1988
- Visualization and analysis of mural thrombogenesis on collagen, polyurethane and nylonBiomaterials, 1986
- The Design, Fabrication and Evaluation of a Trileaflet Prosthetic Heart ValveJournal of Biomechanical Engineering, 1980