A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform
- 18 August 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (17), 5341-5357
- https://doi.org/10.1088/0031-9155/54/17/017
Abstract
Our group has constructed the small animal radiation research platform (SARRP) for delivering focal, kilo-voltage radiation to targets in small animals under robotic control using cone-beam CT guidance. The present work was undertaken to support the SARRP’s treatment planning capabilities. We have devised a comprehensive system for characterizing the radiation dosimetry in water for the SARRP and have developed a Monte Carlo dose engine with the intent of reproducing these measured results. We find that the SARRP provides sufficient therapeutic dose rates ranging from 102 to 228 cGy min−1 at 1 cm depth for the available set of high-precision beams ranging from 0.5 to 5 mm in size. In terms of depth–dose, the mean of the absolute percentage differences between the Monte Carlo calculations and measurement is 3.4% over the full range of sampled depths spanning 0.5–7.2 cm for the 3 and 5 mm beams. The measured and computed profiles for these beams agree well overall; of note, good agreement is observed in the profile tails. Especially for the smallest 0.5 and 1 mm beams, including a more realistic description of the effective x-ray source into the Monte Carlo model may be important.Keywords
This publication has 10 references indexed in Scilit:
- Image-guided small animal radiation research platform: calibration of treatment beam alignmentPhysics in Medicine & Biology, 2009
- High-Resolution, Small Animal Radiation Research Platform With X-Ray Tomographic Guidance CapabilitiesInternational Journal of Radiation Oncology*Biology*Physics, 2008
- MicroRT—Small animal conformal irradiatorMedical Physics, 2007
- Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scannerMedical Physics, 2007
- WE-D-330A-09: An Image-Guided Irradiator for Pre-Clinical Radiation Therapy StudiesMedical Physics, 2006
- Precise radiochromic film dosimetry using a flat-bed document scannerMedical Physics, 2005
- Monte Carlo modelling of external radiotherapy photon beamsPhysics in Medicine & Biology, 2003
- Monte Carlo modelling of radiotherapy kV x-ray unitsPhysics in Medicine & Biology, 1999
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995
- A protocol for the determination of absorbed dose from high‐energy photon and electron beamsMedical Physics, 1983