Teleophthalmology link between a primary health care centre and a reference hospital

Abstract
We have evaluated a teleophthalmology service linking a primary health care centre and an eye clinic at a reference hospital. General practitioners at the primary care centre serving a population of 15,000 and ophthalmologists at the reference hospital participated in this study. Eye fundus digital images were taken from 278 eye fundi of 139 consecutive patients with clinical conditions that could potentially produce fundus alterations. Fundus images were obtained with a non-mydriatic fundus camera (Canon CR6-45M) and were electronically sent reference hospital where ophthalmologist inspected the images and returned the diagnosis. In 18 patients (13%) the images did not have good enough quality to exclude eye fundus lesions. In 24 patients (17%) clear eye fundus alterations were found in at least one eye. In 14 patients (10%) there were image features suggesting retinal alterations that could not be confirmed by image inspection. Media opacity (13 eyes, 5%, seven patients, 5%) was the most common cause of poor image quality. The most difficult assessment was the evaluation of optic nerve head cupping. Retinal oedema was not observable in the digital images. In our experience teleopthalmology services seem to be an effective alternative for eye fundus diagnosis and patient follow-up.