Evaluation of Different Ventricular Pacing Sites in Patients With Severe Heart Failure
- 18 November 1997
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (10), 3273-3277
- https://doi.org/10.1161/01.cir.96.10.3273
Abstract
Background Multisite ventricular pacing has recently been proposed as an additional treatment for patients with severe congestive heart failure. To further assess the potential value of this technique, we compared the acute hemodynamic changes associated with pacing the right ventricular apex (RVA) or outflow tract (RVOT) alone, the left ventricle (LV) alone, or biventricular (BIV) pacing of the RVA and LV together. Methods and Results Acute hemodynamic findings were measured in 27 patients with severe heart failure despite optimal therapy and either first-degree AV block and/or an intraventricular conduction defect. In the 23 patients with a high pulmonary capillary wedge pressure (PCWP) (>15 mm Hg), data were collected after transvenous pacing at different ventricular sites in either the VDD mode (AV delay=100 ms) or the VVI mode in patients with atrial fibrillation (n=6). The mean baseline cardiac index was 1.82 L · min−1 · m−2. Mean±SD baseline systolic blood pressure (SBP) (118.5±15.2 mm Hg), PCWP (26.4±6.6 mm Hg), and V-wave amplitude (39.1±14.6 mm Hg) were similar before and after either RVA or RVOT pacing. In contrast, LV-based pacing (either LV alone or BIV pacing) resulted in higher SBP (P<.03) and lower PCWP (P<.01) and V-wave amplitude (P<.001) than either baseline or RV pacing measurements. With LV pacing alone, SBP, PCWP, and V waves were 126.5±15.1, 20.7±5.9, and 25.5±8.1 mm Hg, respectively. The results with LV pacing alone were similar to those obtained with BIV pacing. Conclusions In patients with severe congestive heart failure, both LV pacing alone and BIV pacing resulted in a similar and significant acute improvement in SBP, PCWP, and V-wave amplitude compared with baseline measurements and RV pacing alone. These results provide a strong basis for initiating long-term studies examining the chronic effects of LV-based pacing in patients with medically refractory congestive heart failure.Keywords
This publication has 9 references indexed in Scilit:
- Multisite Pacing for End‐Stage Heart Failure: Early ExperiencePacing and Clinical Electrophysiology, 1996
- What is the role of pacing in dilated cardiomyopathy?European Heart Journal, 1996
- Dual-chamber pacing with a short atrioventricular delay in congestive heart failure: A randomized studyJournal of the American College of Cardiology, 1995
- Results of atrioventricular synchronous pacing with optimized delay in patients with severe congestive heart failureThe American Journal of Cardiology, 1995
- Acute hemodynamic effects of atrio-biventricular pacing in humansThe Annals of Thoracic Surgery, 1995
- Mechanism of hemodynamic improvement by dual-chamber pacing for severe left ventricular dysfunction: An acute Doppler and catheterization hemodynamic studyJournal of the American College of Cardiology, 1995
- Four Chamber Pacing in Dilated CardiomyopathyPacing and Clinical Electrophysiology, 1994
- VDD Pacing at Short Atrioventricular Intervals Does Not Improve Cardiac Output in Patients with Dilated Heart FailurePacing and Clinical Electrophysiology, 1994
- Usefulness of physiologic dual-chamber pacing in drug-resistant idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1990