Nanoscale elemental imaging of semiconductor materials using focused ion beam secondary ion mass spectrometry
- 1 November 1999
- journal article
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures
- Vol. 17 (6), 2476-2482
- https://doi.org/10.1116/1.591115
Abstract
The semiconductor industry demands elemental information from ever smaller regions. The sensitivity of secondary ion mass spectrometry, coupled with the lateral resolution of a focused ion beam, can provide nanoscale elemental data that are competitive with that from other analytical techniques. Ion images of the sidewalls in repetitive semiconductor features tilted to present a large surface area have shown boron contamination after an etch process. The boron is removed by a specific cleaning step. Spot defect analysis was enhanced by the use of mass spectra that provide information on a range of elements before the defect is removed by sputtering. Ion implanted samples were analyzed in cross section and the implant shape detected. Summation of the secondary ion counts in the implant cross section over a few micrometers resulted in detection limits below 0.1 at. %. Implantation profiles have been detected for Al, Cr, Na, Li, and K without the aid of secondary ion enhancing species, such as oxygen or cesium.Keywords
This publication has 10 references indexed in Scilit:
- Development of ion and electron dual focused beam apparatus for high spatial resolution three-dimensional microanalysis of solid materialsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 1998
- Behavior of Gallium Secondary Ion Intensity in Gallium Focused Ion Beam Secondary Ion Mass SpectrometryJapanese Journal of Applied Physics, 1997
- A focused ion beam secondary ion mass spectroscopy systemJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 1995
- Applications of focused ion beams in microelectronics production, design and developmentSurface and Interface Analysis, 1995
- Ambient oxygen effect in Ga+ FIB‐SIMSSurface and Interface Analysis, 1994
- Recent advances in application of focused ion beam technologyMicroelectronic Engineering, 1993
- Relative sensitivity factors for positive atomic and molecular ions sputtered from Si and GaAsJournal of Vacuum Science & Technology A, 1991
- Focused ion beam secondary ion mass spectrometry: Ion images and end-point detectionJournal of Vacuum Science & Technology B, 1989
- Imaging SIMS at 20 nm Lateral Resolution: Exploratory Research ApplicationsPublished by Springer Nature ,1986
- HIGH SPATIAL RESOLUTION SIMS WITH THE UC-HRL SCANNING ION MICROPROBELe Journal de Physique Colloques, 1984