Prospective Randomized Study of a Protein-Based Tissue Adhesive Used as a Hemostatic and Structural Adjunct in Cardiac and Vascular Anastomotic Repair Procedures
- 1 August 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 197 (2), 243-252
- https://doi.org/10.1016/s1072-7515(03)00376-4
Abstract
The purpose of this study was to determine whether adjunctive use of the bovine serum albumin and glutaraldehyde tissue adhesive BioGlue (BioGlue Surgical Adhesive; CryoLife, Inc) could reduce the rate of anastomotic bleeding in patients undergoing cardiac and vascular repair procedures when compared with a standard repair control. This was a prospective multicenter, randomized, controlled clinical trial conducted in accordance with the IRB at each participating institution. A total of 151 patients consented to participation and were randomly assigned to standard repair plus BioGlue (n = 76) or standard repair alone (n = 75). These two groups were statistically homogeneous for age, gender, race, procedure, and number of anastomoses. Patients underwent cardiac procedures (n = 49), aortic procedures (n = 105), or peripheral vascular procedures (n = 48). Anastomotic bleeding was significantly reduced in the BioGlue group (18.8% of anastomoses) compared with the control group (42.9% of anastomoses, p < 0.001). Pledget use was reduced in the BioGlue group (26.2%) compared with the control group (35.9%, p = 0.047). Days in the ICU and total days in the hospital were slightly higher in the control group. Adverse event profiles were equivalent between the two groups except for occurrence of neurological defects, which were threefold less in the BioGlue group (p = 0.009). This study demonstrates that using BioGlue as an adjunct to standard repair methods is safe and significantly reduces the occurrence of intraoperative anastomotic site bleeding in cardiac and vascular repair patients. Using BioGlue along suture lines reinforces anastomoses, thus minimizing pledget use.Keywords
This publication has 16 references indexed in Scilit:
- BioGlue surgical adhesive—an appraisal of its indications in cardiac surgeryThe Annals of Thoracic Surgery, 2002
- Use of “BioGlue” in aortic surgical repairThe Annals of Thoracic Surgery, 2001
- Prevention of residual ventricular septal defects with fibrin sealantThe Annals of Thoracic Surgery, 1995
- Outcome and expansion rate of 57 thoracoabdominal aortic aneurysms managed nonoperativelyThe American Journal of Surgery, 1995
- Prospective evaluation of minimal blood use for ascending aorta and aortic arch operationsThe Annals of Thoracic Surgery, 1995
- Experience with 1509 patients undergoing thoracoabdominal aortic operationsJournal of Vascular Surgery, 1993
- Clinical Experience with Fibrin Glue for Local Bleeding Control and Sealing of Vascular ProsthesesThe Thoracic and Cardiovascular Surgeon, 1982
- Clinical Application of Fibrin Glue in Cardiovascular SurgeryThe Thoracic and Cardiovascular Surgeon, 1982
- Clinical Experience with Fibrin Glue in Cardiac SurgeryThe Thoracic and Cardiovascular Surgeon, 1981
- The Use of Fibrin Glue for Sealing Vascular Prostheses of High PorosityThe Thoracic and Cardiovascular Surgeon, 1981