Multiplex LightCycler PCR Assay for Detection and Differentiation of Bordetella pertussis and Bordetella parapertussis in Nasopharyngeal Specimens
Open Access
- 1 January 2002
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 40 (1), 96-100
- https://doi.org/10.1128/jcm.40.1.96-100.2002
Abstract
A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS 481 and IS 1001 of B. pertussis and B. parapertussis , respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis ) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS 481 ) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens ( n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different ( P = 0.0654). The insertion sequence IS 481 is also present in Bordetella holmesii ; specimens containing B . holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B . pertussis and B . parapertussis in nasopharyngeal specimens.Keywords
This publication has 10 references indexed in Scilit:
- Recovery of Bordetella holmesii from patients with pertussis-like symptoms: use of pulsed-field gel electrophoresis to characterize circulating strains.2000
- Recovery of Bordetella holmesii from Patients with Pertussis-Like Symptoms: Use of Pulsed-Field Gel Electrophoresis To Characterize Circulating StrainsJournal of Clinical Microbiology, 2000
- Microbiological and Serological Diagnosis of PertussisClinical Infectious Diseases, 1999
- Bordetella holmesii-Like Organisms Isolated from Massachusetts Patients with Pertussis-Like SymptomsEmerging Infectious Diseases, 1999
- Bordetella holmesii–Like Organisms Associated with Septicemia, Endocarditis, and Respiratory FailureClinical Infectious Diseases, 1998
- Case definitions for infectious conditions under public health surveillance. Centers for Disease Control and Prevention.1997
- Polymerase chain reaction for the detection of Bordetella pertussis in clinical nasopharyngeal aspiratesJournal of Medical Microbiology, 1996
- Identification of Bordetella pertussis in nasopharyngeal swabs by PCR amplification of a region of the adenylate cyclase geneJournal of Medical Microbiology, 1993
- Specific identification of Bordetella pertussis by the polymerase chain reactionResearch in Microbiology, 1989
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960