Measurement of space charge distribution in acetophenone coated low-density polyethylene
- 22 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 32-35 vol.1
- https://doi.org/10.1109/ceidp.1997.634552
Abstract
Short interval measurement of space charge formation in acetophenone coated low-density polyethylene (LDPE) under DC high voltage stress is carried out using an improved pulsed electro-acoustic (PEA) method. This system makes it possible to measure the space charge formation at intervals of less than one second. Using this system, a dynamic space charge formation in acetophenone coated LDPE was observed at 2 second intervals during the application of DC voltage and polarity reversal. From the experimental results, it was found that a charge packet appeared near the anode within a few seconds, which subsequently moved towards the cathode.Keywords
This publication has 1 reference indexed in Scilit:
- Experimental observation of charge transport and injection in XLPE at polarity reversalJournal of Physics D: Applied Physics, 1992