Graphite Furnace Atomic Absorption Spectrometric Determination of Ultra-Trace Levels of Cobalt after Solvent Extraction Using W/O/W Emulsions as Liquid Surfactant Membranes
- 28 June 1990
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 6 (3), 401-405
- https://doi.org/10.2116/analsci.6.401
Abstract
A high-enrichment method by liquid-liquid extraction using liquid surfactant membranes was developed for the determination of cobalt at pg cm-3 levels by graphite furnace atomic absorption spectrometry (GF-AAS). Two cubic centimeters of w/o [water in oil, in this case dilute hydrochloric acid in kerosene (1:1) containing 2-ethylhexyl hydrogen 2-ethylhexylphosphonate (PC-88A)] emulsion droplets coated with sorbitan monooleate are dispersed in a resulting volume of 1000cm3 of an aqueous sample solution (pH 4.7-5.8) containing less than 1mg of cobalt(II). The analyte is extracted into the organic phase to form a complex with PC-88A and successively back-extracted into the inner acidic aqueous phase. After the w/o emulsion phase is separated from the outer aqueous phase, the emulsions are demulsified into the organic and inner aqueous phases. The cobalt content is then determined by GF-AAS with an injection volume of 10mm3 of the inner aqueous phase. By this procedure, a concentration factor of 550 was achieved for cobalt(II). As a result, the detection limit of cobalt was 10pg cm-3, and the calibration graph was linear up to 1mg cm-3 of cobalt(II). The relative standard deviation for ten replicate measurements of 50pg cm-3 cobalt(II) was 7.1%. The results of an analysis of simulated nuclear reactor coolant water are given.Keywords
This publication has 5 references indexed in Scilit:
- Microporous polytetrafluoroethylene tube separator for the determination of beryllium by flow injection-or suction-flow-solvent extraction followed by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1988
- Inductively Coupled Plasma Atomic Emission Spectrometric Determination of Copper by Suction-Flow On-Line Liquid–Liquid Extraction of Its Macrocyclic Dioxotetramine ChelateBulletin of the Chemical Society of Japan, 1987
- Sensitivity enhancement for inductively-coupled plasma atomic emission spectrometry of cadmium by suction-flow on-line ion-exchange preconcentrationAnalytica Chimica Acta, 1986
- Determination of cadmium by suction-flow liquid-liquid extraction combined with inductively-coupled plasma atomic emission spectrometryAnalytica Chimica Acta, 1985
- Electrocatalytic detection of cobalt separated by ion exchange chromatographyAnalytical Chemistry, 1979