High-sensitivity optical monitoring of a micro-mechanical resonator with a quantum-limited optomechanical sensor
Preprint
- 19 May 2006
Abstract
We experimentally demonstrate the high-sensitivity optical monitoring of a micro-mechanical resonator and its cooling by active control. Coating a low-loss mirror upon the resonator, we have built an optomechanical sensor based on a very high-finesse cavity (30000). We have measured the thermal noise of the resonator with a quantum-limited sensitivity at the 10^-19 m/rootHz level, and cooled the resonator down to 5K by a cold-damping technique. Applications of our setup range from quantum optics experiments to the experimental demonstration of the quantum ground state of a macroscopic mechanical resonator.All Related Versions
- Version 1, 2006-05-19, ArXiv
- Published version: Physical Review Letters, 97 (13), 133601.