Neodymium:YAG laser damage on silicone intraocular lenses
- 1 September 1994
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 20 (5), 527-533
- https://doi.org/10.1016/s0886-3350(13)80233-7
Abstract
In this study we examined 17 explanted silicone intraocular lenses (IOLs) (two one-piece, 15 three-piece) that had evidence of neodymium:YAG (Nd:YAG) laser damage. The majority of lenses (47.1%) had been explanted because of persistent pigment deposits and chronic inflammation. Decentration or IOL dislocation had occurred with 29.4% of lenses. All 17 patients had had Nd:YAG laser posterior capsulectomy, anterior surface polishing, or both; treatments ranged from one to 13 times. By both clinical and gross examination, the laser lesions appeared dark. This was misinterpreted by some opthalmologists as pigment deposits and some patients had additional Nd:YAG laser treatment, which increased the severity of the laser damage. The mean depth of laser damage on the IOLs was 143 +/- 113.4 microns. It was between 51 and 175 microns in approximately 61.0% and deeper than 300 microns (maximum 660 microns) in 9.3%. We compared the explanted IOLs with silicone IOLs that were experimentally damaged using standard power levels from 0.3 to 3.0 mJ and different focal areas. The appearance of the experimentally induced laser burns was equivalent to that on the explanted IOLs, especially the dark laser pits. Since the laser lesions may resemble pigment deposits on slitlamp examination, we recommend careful examination of patients prior to planned laser therapy.Keywords
This publication has 18 references indexed in Scilit:
- Posterior capsule opacificationSurvey of Ophthalmology, 1992
- Incidence of retinal detachment following Nd:YAG capsulotomy after cataract surgeryJournal of Cataract & Refractive Surgery, 1992
- Cystoid Macular Edema, Retinal Detachment, and Glaucoma after Nd:YAG Laser Posterior CapsulotomyAmerican Journal of Ophthalmology, 1991
- Neodymium:YAG laser damage to UV-absorbing poly(methyl methacrylate) and UV-absorbing MMA-HEMA-EGDMA polymer intraocular lens materialsJournal of Cataract & Refractive Surgery, 1991
- Intraocular lens damage from Nd:YAG laser pulses focused in the vitreous Part II: Mode-locked lasersJournal of Cataract & Refractive Surgery, 1988
- Intraocular lens damage from Nd:YAG laser pulses focused in the vitreous Part I: Q-switched lasersJournal of Cataract & Refractive Surgery, 1988
- Effect of the Nd:YAG laser on polymethylmethacrylate, HEMA copolymer, and silicone intraocular materialsJournal of Cataract & Refractive Surgery, 1987
- Glare disability secondary to YAG laser intraocular lens damageJournal of Cataract & Refractive Surgery, 1987
- Neodymium:YAG Laser Damage ThresholdOphthalmology, 1987
- Pathology and physics of YAG-laser intraocular lens damageJournal of Cataract & Refractive Surgery, 1987