Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT
- 1 March 1994
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 39 (3), 425-437
- https://doi.org/10.1088/0031-9155/39/3/010
Abstract
The authors evaluated small-field-of-view ultra-high-resolution pinhole collimation for a rotating-camera SPECT system that could be used to image small laboratory animals. Pinhole collimation offers distinct advantages over conventional parallel-hole collimation when used to image small objects. Since geometric sensitivity increases markedly for points close to the pinhole, small-diameter and high-magnification pinhole geometries may be useful for selected imaging tasks when used with large-field-of-view scintillation cameras. The use of large magnifications can minimize the loss of system resolution caused by the intrinsic resolution of the scintillation camera. A pinhole collimator has been designed and built that can be mounted on one of the scintillation cameras of a triple-head SPECT system. 3 Pinhole inserts with approximate aperture diameters of 0.6, 1.2 and 2.0 mm have been built and can be mounted individually on the collimator housing. When a ramp filter is used with a 3D filtered backprojection (FBP) algorithm, the 3 apertures have in-plane SPECT spatial resolutions (FWHM) at 4 cm of 1.5, 1.9 and 2.8 mm, respectively. In-air point source sensitivities at 4 cm from the apertures are 0.9, 2.6 and 5.7 counts s-1 mu Ci-1 (24, 70 and 154 counts s-1 MBq-1) for the 0.6, 1.2 and 2.0 mm apertures, respectively. In vitro image quality was evaluated with a micro-cold-rod phantom and a micro-Defrise phantom using both the 3D FBP algorithm and a 3D maximum likelihood-expectation maximization algorithm. In vivo image quality was evaluated using 2 (315 and 325 g) rats. Ultra-high-resolution pinhole SPECT is an inexpensive and simple approach for imaging small animals that can be used with existing rotating-camera SPECT systems.Keywords
This publication has 10 references indexed in Scilit:
- A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotationPhysics in Medicine & Biology, 1994
- Simulated annealing image reconstruction method for a pinhole aperture single photon emission computed tomograph (SPECT)IEEE Transactions on Medical Imaging, 1990
- Pinhole emission computed tomography: method and experimental evaluationPhysics in Medicine & Biology, 1990
- Maximum likelihood reconstruction for cone beam SPECT: development and initial testsPhysics in Medicine & Biology, 1989
- Cone beam collimation for single photon emission computed tomography: Analysis, simulation, and image reconstruction using filtered backprojectionMedical Physics, 1986
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984
- An Inversion Formula for Cone-Beam ReconstructionSIAM Journal on Applied Mathematics, 1983
- Physical Factors Affecting Quantitative Measurements Using Camera-Based Single Photon Emission Computed Tomography (Spect)IEEE Transactions on Nuclear Science, 1981
- Single Photon Emission Computed Tomography Using Multi-Slice Fan Beam CollimatorsIEEE Transactions on Nuclear Science, 1979