Instantaneous Increase in Mean Circulatory Pressure and Cardiac Output at Onset of Muscular Activity
- 1 September 1962
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 11 (3), 431-441
- https://doi.org/10.1161/01.res.11.3.431
Abstract
In dogs with their spinal cords cut, sudden maximal muscular contraction in the lower half of the body caused the mean circulatory pressure to rise instantaneously to three times normal and the cardiac output to rise to an average of 40 per cent above normal. This instantaneous effect was not blocked by sympathetic blockade with hexamethonium but was blocked by skeletal muscle blockade with decamethonium. Furthermore, because of the transected cord, no cardiac reflex effects were observed. Therefore, it was concluded that skeletal muscle activity compresses the intra-muscular and intra-abdominal vessels and thereby increases the mean circulatory pressure. Evidence is presented to show that this, in turn, translocates blood into the heart and that the heart then responds in conformity with Starling's principle of cardiac adaptation to increase the cardiac output.Keywords
This publication has 17 references indexed in Scilit:
- The Use of an Analog Computer for Analysis of Control Mechanisms in the CirculationProceedings of the IRE, 1959
- Integrative Cardiovascular Physiology: A Mathematical Synthesis of Cardiac and Blood Vessel HemodynamicsThe Quarterly Review of Biology, 1959
- Autonomic Balance in Cardiac ControlAmerican Journal of Physiology-Legacy Content, 1958
- Pressure-Circumference Relations of Left VentricleAmerican Journal of Physiology-Legacy Content, 1956
- Effect of Mean Circulatory Filling Pressure and Other Peripheral Circulatory Factors on Cardiac OutputAmerican Journal of Physiology-Legacy Content, 1955
- Energy and Hydraulic Gradients Along Systemic VeinsAmerican Journal of Physiology-Legacy Content, 1954
- RÔLE OF THE “STATIC BLOOD PRESSURE” IN ABNORMAL INCREMENTS OF VENOUS PRESSURE, ESPECIALLY IN HEART FAILURE. II. CLINICAL AND EXPERIMENTAL STUDIESThe American Journal of the Medical Sciences, 1940
- Observations ON THE PATHOLOGY OF CARDIAC DROPSY: Being the Oliver-Sharpey Lectures delivered before the Royal College of Physicians of London, May, 1917BMJ, 1917
- On the mechanical factors which determine the output of the ventriclesThe Journal of Physiology, 1914
- The Arris and Bale Lectures ON SOME POINTS IN THE PATHOLOGY OF HEART DISEASE.The Lancet, 1897