Maximal Treadmill Stress Testing for Cardiovascular Evaluation

Abstract
Experience with a maximal treadmill stress testing procedure which is relatively safe, simple, and reproducible is reported. It has been used in normal persons and cardiac patients with ages ranging from 7 to 83 years. There have been no deaths in our total experience of 4,028 maximal capacity stress tests. Maximal capacity is predicted by the patient's peak predicted pulse rate. Sixty-three per cent of those with ischemic S-T segments did not experience pain of any type.