Sensitivity of hemozoin detection by automated flow cytometry in non‐ and semi‐immune malaria patients
Open Access
- 22 August 2003
- journal article
- research article
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 55B (1), 46-51
- https://doi.org/10.1002/cyto.b.10039
Abstract
Background: Cell‐Dyn automated blood cell analyzers use laser flow cytometry technology, allowing detection of malaria pigment (hemozoin) in monocytes. We evaluated the value of such an instrument to diagnose malaria in febrile travelers returning to Berlin, Germany, the relation between the instrument's performance and the patients' immune status, and the capacity to increase its sensitivity.Methods: Malaria diagnosis was routinely established by thick‐film microscopy. The patients' immune status was determined by an indirect fluorescent antibody test. Hemozoin detection was performed with a Cell‐Dyn 3000. To assess the capacity for sensitivity increase, the relative frequencies of pigment‐containing monocytes were determined for a subgroup of patients with the Cell‐Dyn 3000 in comparison with a flow cytometer specifically adapted to rare‐event analysis.Results: Of 403 patients screened microscopically, 107 had malaria. Overall sensitivity with the Cell‐Dyn 3000 reached 48.6% (73.7% in semi‐immune and 28.6% in nonimmune individuals; P < 0.0001). Specificity was 96.2%. The detection limit was at a relative concentration of 2 × 10−4 pigment‐containing monocytes (PCMs). By employing rare‐event flow cytometry, the detection limit decreased to 3.25 × 10−5, thus yielding a considerably increased sensitivity for the subgroup studied.Conclusions: The correlation between immune status and relative concentration of PCMs explains the failure of the routine instrument for nonimmune patients and its significantly higher sensitivity for semi‐immune individuals. The technique can be significantly improved by rare‐event flow cytometry. Cytometry Part B (Clin. Cytometry) 55B:46–51, 2003.Keywords
This publication has 19 references indexed in Scilit:
- Rapid Diagnostic Tests for Malaria ParasitesClinical Microbiology Reviews, 2002
- Diagnosis by Automated Blood AnalyzerClinical Infectious Diseases, 2001
- Relative frequency of malaria pigment-carrying monocytes of nonimmune and semi-immune patients from flow cytometric depolarized side scatterCytometry, 2001
- Avoiding Misdiagnosis of Malaria: A Novel Automated Method Allows Specific Diagnosis, even in the Absence of Clinical SuspicionEmerging Infectious Diseases, 1999
- Intraleucocytic malaria pigment and clinical severity of malaria in childrenTransactions of the Royal Society of Tropical Medicine and Hygiene, 1998
- The laboratory diagnosis of malariaClinical and Laboratory Haematology, 1997
- Malaria pigment in leucocytesTransactions of the Royal Society of Tropical Medicine and Hygiene, 1995
- Intraleucocytic malaria pigment and prognosis in severe malariaTransactions of the Royal Society of Tropical Medicine and Hygiene, 1995
- Identification of the four human malaria parasite species in field samples by the polymerase chain reaction and detection of a high prevalence of mixed infectionsMolecular and Biochemical Parasitology, 1993
- The Fluorescent Antibody Test for MalariaCRC Critical Reviews in Clinical Laboratory Sciences, 1971