External Quality Assessment for Molecular Detection of Bordetella pertussis in European Laboratories
- 1 January 2005
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 43 (1), 30-35
- https://doi.org/10.1128/jcm.43.1.30-35.2005
Abstract
Although the PCR for the detection of Bordetella pertussis is routinely performed in diagnostic laboratories, no quality assessment program has so far been described. We report on the results obtained with two external quality assessment proficiency panels sent to European laboratories. The first proficiency panel contained a series of dilutions of three previously characterized B. pertussis clinical isolates and two negative controls. No false-positive results were reported by six laboratories providing seven data sets. The reported limits of detection of the three B. pertussis strains varied between 4 and 4,000, 9 and 9,000, and 3 and 30,000 CFU/ml, respectively. The second proficiency panel, composed of a series of dilutions of reference strains of B. pertussis , B. holmesii , B. hinzii , and B. bronchiseptica , as well as negative controls, was sent to nine laboratories. One laboratory reported a negative result for a sample and reported a B. parapertussis -positive sample to be positive for B. pertussis . By using the B. pertussis -specific target gene pertactin, one laboratory detected B. pertussis with 100% specificity. All other laboratories, which used IS 481 -based assays, reported positive results for the samples containing B. holmesii and B. bronchiseptica , species that have occasionally been recovered from human respiratory samples. These data show that the choice of the target gene is particularly critical for the species specificity of B. pertussis PCR assays.Keywords
This publication has 44 references indexed in Scilit:
- Laboratory diagnosis of pertussis infections: the role of PCR and serologyJournal of Medical Microbiology, 2004
- Fate of Streptococcus pyogenes and epithelial cells following internalizationJournal of Medical Microbiology, 2004
- Severe and unrecognised: pertussis in UK infantsArchives of Disease in Childhood, 2003
- Cavitary Pneumonia in an AIDS Patient Caused by an Unusual Bordetella bronchiseptica Variant Producing Reduced Amounts of Pertactin and Other Major AntigensJournal of Clinical Microbiology, 2002
- Semiquantitative Polymerase Chain Reaction Enzyme Immunoassay for the Diagnosis of PertussisEuropean Journal of Clinical Microbiology & Infectious Diseases, 1999
- Failure of Physicians to Consider the Diagnosis of Pertussis in ChildrenClinical Infectious Diseases, 1999
- Simultaneous Amplification of Bordetella Repeated Insertion Sequences and Toxin Promoter Region Gene by Polymerase Chain ReactionImmunopharmacology and Immunotoxicology, 1999
- A second European collaborative study on polymerase chain reaction forToxoplasma gondii, involving 15 teamsFEMS Microbiology Letters, 1998
- Epidemiology and prevention of pertussisCurrent Opinion in Pediatrics, 1997
- A Clinical Validation of Bordetella pertussis and Bordetella parapertussis Polymerase Chain Reaction: Comparison with Culture and Serology using Samples from Patients with Suspected Whooping Cough from a Highly Immunized PopulationThe Journal of Infectious Diseases, 1996