Abstract
Iron-loss measurements on grain-oriented silicon-iron transformer steel have been made at frequencies in the range 0–25 c/s. The results indicate that the very high anomalous losses observed are due mainly, if not wholly, to a frequency-dependent hysteresis component coming into existence, particularly at frequencies of the order of a few cycles per second.