A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation.
- 1 July 1978
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 58 (1), 90-94
- https://doi.org/10.1161/01.cir.58.1.90
Abstract
Ventricular defibrillation was acheived in active conscious dogs with a chronically implanted automatic system composed of a defibrillator and an alternating current fibrillator. The hermetically sealed defibrillator is encased in titanium, weighs 250 g and has a volume of 145 ml. The sensor continuously monitors ventricular electircal activity and recognizes fibrillation by the absence of isoelectric potential segments. Fibrillation is induced by placing a magnet over the implanted fibrillator. The resulting syncope closely resembles the clinical entity of sudden death, while the defibrillator automatically restores normal rhythm with a truncated exponential pulse of 30 J, 15 seconds after the onset of the arrhythmia. The operational status of the defibrillator can be tested in vitro and noninvasively in vivo with an external analyzer. This experimental model allows for the first time a long-term study of the automatic implantable defibrillator approach to prevent sudden death from ventricular fibrillation under a variety of physiopathologic conditions.This publication has 17 references indexed in Scilit:
- Ventricular Premature Beats and Mortality after Myocardial InfarctionNew England Journal of Medicine, 1977
- Sudden death in the year following myocardial infarctionAmerican Journal Of Medicine, 1977
- Prognostic significance of ventricular dys-rhythmias 1 year after myocardial infarctionThe American Journal of Cardiology, 1976
- Relation of ventricular arrhythmias in the late hospital phase of acute myocardial infarction to sudden death after hospital dischargeAmerican Journal Of Medicine, 1975
- Editorial: Prehospital coronary care.Heart, 1974
- Ventricular defibrillation in the dog using implanted and partially implanted electrode systemsThe American Journal of Cardiology, 1974
- Ventricular arrhythmias associated with sudden death in survivors of acute myocardial infarctionThe American Journal of Cardiology, 1974
- Relationship between electrode geometry and effectiveness of ventricular defibrillation in the dog with catheter having one electrode in right ventricle and other electrode in superior vena cava, or external jugular vein, or bothCardiovascular Research, 1973
- TRANSVENOUS AUTOMATIC DEFIBRILLATOR — PRELIMINARY CLINICAL TESTS OF ITS DEFIBRILLATING SUBSYSTEMAsaio Journal, 1972
- A MOBILE INTENSIVE-CARE UNIT IN THE MANAGEMENT OF MYOCARDIAL INFARCTIONThe Lancet, 1967