The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI
- 1 November 1992
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 28 (1), 9-24
- https://doi.org/10.1002/mrm.1910280103
Abstract
The importance to MR image quality of the order of acquisition of different phaseencoded views with sequences that have variable TR and TE has been recently reported. It has been shown that the effective point spread function (PSF) may be manipulated by varying TE or TR, or both, with each phase-encoding step. This paper explores the behavior of the PSF in a variable TE sequence and its dependence on both imaging and tissue parameters. It is shown that the PSF is different for each tissue type and that its effect on tissue contrast is a function of both the shape and size of the structure. The important problem of signal loss from small objects that arises when the effective PSF is broad and the difficulty in detecting this phenomenon in practical MR images is illustrated. It is shown that the PSF can produce significant blurring and loss of object contrast in fast spin-echo images but that this blurring may be not be obvious in practice because the noise is unaffected by the PSF. It is also shown that the signal from small lesions with short T2 can easily be lost through this blurring mechanism. The importance of signal loss from small objects and its implication for the clinical use of such sequences as fast spinecho or rapid acquisition relaxation-enhanced and echo planar imaging is stressed.© 1992 Academic Press,Inc.Keywords
This publication has 9 references indexed in Scilit:
- T2-weighted spin-echo pulse sequence with variable repetition and echo times for reduction of MR image acquisition time.Radiology, 1991
- Comparing the FAISE method with conventional dual‐echo sequencesJournal of Magnetic Resonance Imaging, 1991
- Contrast, Resolution, and Detectability in MR ImagingJournal of Computer Assisted Tomography, 1991
- Strategies to improve contrast in turboFLASH imaging: Reordered phase encoding and K‐space segmentationJournal of Magnetic Resonance Imaging, 1991
- The importance of phase‐encoding order in ultra‐short TR snapshot MR imagingMagnetic Resonance in Medicine, 1990
- Contrast manipulation and artifact assessment of 2D and 3D RARE sequencesMagnetic Resonance Imaging, 1990
- Multiecho imaging sequences with low refocusing flip anglesJournal of Magnetic Resonance (1969), 1988
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986
- REAL-TIME ECHO-PLANAR IMAGING BY NMRBritish Medical Bulletin, 1984