Optical coherence tomography assessment of capsule closure after cataract surgery
- 1 February 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (2), 330-336
- https://doi.org/10.1016/j.jcrs.2004.04.057
Abstract
Purpose: To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery. Setting: Medical University of Vienna, Department of Ophthalmology, Vienna, Austria. Methods: This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined. Results: One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 μm in the 1-piece acrylic IOL group, 161 μm in the 3-piece acrylic IOL group, and 220 μm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99). Conclusions: Optical coherence tomography produced cross-sectional tomograms of capsule–IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.Keywords
This publication has 15 references indexed in Scilit:
- Adhesion of soluble fibronectin, vitronectin, and collagen type IV to intraocular lens materialsJournal of Cataract & Refractive Surgery, 2003
- Mathematical modeling of the forces between an intraocular lens and the capsuleJournal of Cataract & Refractive Surgery, 2002
- Elapsed time for capsular apposition to intraocular lens after cataract surgery 1 1The authors have no proprietary interest in any of the materials described in this article.Ophthalmology, 2002
- Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lensesJournal of Cataract & Refractive Surgery, 2002
- Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyesJournal of Cataract & Refractive Surgery, 2000
- Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyesJournal of Cataract & Refractive Surgery, 2000
- Resolution-improved dual-beam and standard optical coherence tomography: a comparison.Albrecht von Graefes Archiv für Ophthalmologie, 2000
- Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials 1 2Journal of Cataract & Refractive Surgery, 1999
- Optical Coherence Tomography of Age-related Macular Degeneration and Choroidal NeovascularizationOphthalmology, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986