A systematic evaluation of air cavity dose perturbation in megavoltage x‐ray beams
- 5 May 2000
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 27 (5), 1011-1017
- https://doi.org/10.1118/1.598966
Abstract
The EGS4 Monte Carlo radiation transport code was used to systematically study the dose perturbation near planar and cylindrical air cavities in a water medium irradiated by megavoltage x-ray beams. The variables of the problem included x-ray energy, cavity shape and dimension, and depth of the cavity in water. The Monte Carlo code was initially validated against published measurements and its results were found to agree within 2% with the published measurements. The study results indicate that the dose perturbation is strongly dependent on x-ray energy, field size, depth, and size of cavity in water. For example, the Monte Carlo calculations show dose reductions of 42% and 18% at 0.05 and 2 mm, respectively, beyond the air-water interface distal to the radiation source for a 3 cm thick air slab irradiated by a single 5x5 cm2 15 MV beam. The dose reductions are smaller for a parallel-opposed pair of 5x5 cm2 15 MV x-ray beams, being 21% and 11% for the same depths. The combined set of Monte Carlo calculations showed that the dose reduction near an air cavity is greater for: (a) Smaller x-ray field size, (b) higher x-ray energy, (c) larger air-cavity size, and (d) smaller depth in water where the air cavity is situated. A potential clinical application of these results to the treatment of prostate cancer is discussed.Keywords
This publication has 25 references indexed in Scilit:
- Les complications rectales de la radiothérapieCancer/Radiothérapie, 1997
- Assessment of mucosal underdosing in larynx irradiationInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Implications of tissue heterogeneity for radiosurgery in head and neck tumorsInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Air cavity effects on the radiation dose to the larynx using Co-60, 6 MV, and 10 MV photon beamsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- The influence of air cavities on interface doses for photon beamsInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Early gliottic carcinoma: Underdosage in the vocal cords from megavoltage irradiationInternational Journal of Radiation Oncology*Biology*Physics, 1992
- The Monte Carlo simulation of ion chamber response to60Co-resolution of anomalies associated with interfacesPhysics in Medicine & Biology, 1985
- Underdosing of lesions resulting from lack of electronic equilibrium in upper respiratory air cavities irradiated by 10 mv X-ray beamsInternational Journal of Radiation Oncology*Biology*Physics, 1977
- Build-Up Effects at Air Cavities Measured with Thin Thermoluminescent DosimetersActa Radiologica: Therapy, Physics, Biology, 1976
- Ionization Build-up in Upper Respiratory Air Passages during Teletherapy with Cobalt 60 RadiationThe British Journal of Radiology, 1958