Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke

Abstract
Computed tomography perfusion imaging in acute stroke requires further validation. We aimed to establish the optimal computed tomography perfusion parameters defining the infarct core and critically hypoperfused tissue. Sub-6-h computed tomography perfusion and 24-h magnetic resonance imaging were analysed from 314 consecutive patients with ischaemic stroke. Diffusion-weighted imaging lesion volume at 24 h was used to define the extent of critically hypoperfused tissue (in patients without reperfusion between acute and 24-h time points), and infarct core (in patients with major reperfusion at 24 h). Pixel-based analysis of co-registered computed tomography perfusion and diffusion-weighted imaging was then used to define the optimum computed tomography perfusion thresholds for critically hypoperfused at-risk tissue and infarct core. These optimized acute computed tomography perfusion threshold-based lesion volumes were then compared with 24-h diffusion-weighted imaging infarct volume, as well as 24-h and 90-day clinical outcomes for validation. Relative delay time >2 s was the most accurate computed tomography perfusion threshold in predicting the extent of critically hypoperfused tissue with both receiver operating curve analysis (area under curve 0.86), and the volumetric validation (mean difference between computed tomography perfusion and 24-h diffusion-weighted imaging lesions = 2 cm2, 95% confidence interval 0.5–3.2 cm2). Cerebral blood flow 2 s perfusion lesion was the most accurate computed tomography perfusion threshold at defining infarct core with both receiver operating characteristic analysis (area under curve = 0.85) and the volumetric validation. Using these thresholds, the extent of computed tomography perfusion mismatch tissue (the volume of ‘at-risk’ tissue between the critically hypoperfused and core thresholds) salvaged from infarction correlated with clinical improvement at 24 h ( R 2 = 0.59, P = 0.04) and 90 days ( R 2 = 0.42, P = 0.02). Patients with larger baseline computed tomography perfusion infarct core volume (>25 ml) also had poorer recovery at Day 90 ( P = 0.039). Computed tomography perfusion can accurately identify critically hypoperfused tissue that progresses to infarction without early reperfusion, and the computed tomography perfusion cerebral blood flow infarct core closely predicts the final volume of infarcted tissue in patients who do reperfuse. The computed tomography perfusion infarct core and at-risk measures identified are also strong predictors of clinical outcome. * Abbreviations : DWI : diffusion-weighted imaging NIHSS : National Institutes of Health Stroke Scale